Literature DB >> 32533392

Development and Evaluation of CT-to-3D Ultrasound Image Registration Algorithm in Vertebral Phantoms for Spine Surgery.

Andrew Chan1, Brendan Coutts2, Eric Parent3, Edmond Lou4,5.   

Abstract

Posterior spinal fusion surgery requires careful insertion of screws into the spine to avoid neurologic injury. While current systems use CT-scans, three-dimensional ultrasound (3DUS) could provide guidance by reconstructing the vertebral surface, and then registering a pre-operative vertebral model to that surface for localization. The aim of this study was to evaluate the accuracy and processing time of a custom CT-3DUS registration algorithm. A phantom human vertebra was 3D-printed and scanned with a motion capture-based 3D ultrasound (3DUS) system. Image registration was performed that included a pre-alignment phase using vertebral symmetry information, and then comparing Gaussian pyramid intensity-based registration with iterative-closest-point registration for final transformations. Image registration was performed 192 times while surgical registration between CT and real-world position was performed 84 times. The accuracy of image registration (CT-to-3DUS) was 0.3 ± 0.2 mm and 0.9 ± 0.8° completed in 13.3 ± 2.9 s. The surgical navigation accuracy (CT model to real-world position) of the system was 1.2 ± 0.5 mm and 2.2 ± 2.0° completed in 16.2 ± 3.0 s. Both meet accuracy thresholds of < 2 mm and < 5° required for the surgery. A feasibility study on porcine spine qualitatively showed appropriate overlapping anatomy in CT-3DUS registrations. The usage of 3D ultrasound for navigation has demonstrated accuracy to provide radiation-free image guidance for spine surgery.

Entities:  

Keywords:  3D ultrasound; Image registration; Pedicle screws; Scoliosis; Spine; Ultrasonics

Year:  2020        PMID: 32533392     DOI: 10.1007/s10439-020-02546-5

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  5 in total

1.  3D ultrasound navigation system for screw insertion in posterior spine surgery: a phantom study.

Authors:  Andrew Chan; Eric Parent; Jim Mahood; Edmond Lou
Journal:  Int J Comput Assist Radiol Surg       Date:  2021-11-02       Impact factor: 2.924

2.  Reconstruction Algorithm-Based Ultrasonic and Spiral CT Images in Evaluating the Effects of Dexmedetomidine Anesthesia for Acute Abdomen.

Authors:  Pinghua Tian; Shuhong Zhang; Linling Guo
Journal:  Comput Math Methods Med       Date:  2021-12-28       Impact factor: 2.238

3.  An Orthopedic Auxiliary Diagnosis System Based on Image Recognition Technology.

Authors:  Yang Guo; Chen Chen
Journal:  J Healthc Eng       Date:  2021-11-22       Impact factor: 2.682

4.  The Application of Ultrasound Image in Cancer Diagnosis.

Authors:  Xiaoli Wang; Mei Yang
Journal:  J Healthc Eng       Date:  2021-11-09       Impact factor: 2.682

5.  Accuracy of Pedicle Screw Placement Methods in Pediatrics and Adolescents Spinal Surgery: A Systematic Review and Meta-Analysis.

Authors:  Brigita De Vega; Aida Ribera Navarro; Alexander Gibson; Deepak M Kalaskar
Journal:  Global Spine J       Date:  2021-03-18
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.