Literature DB >> 32521026

Three-Dimensional Assessments of Intraocular Lens Stability With High-Speed Swept-Source Optical Coherence Tomography.

Xixia Ding, Qinmei Wang, Linfeng Xiang, Pingjun Chang, Shenghai Huang, Yun-E Zhao.   

Abstract

PURPOSE: To evaluate the effect of intraocular lens (IOL) optic overlapping on IOL stability and to determine the relationship between the capsulorhexis and IOL movement with the three-dimensional method of swept-source optical coherence tomography (SS-OCT).
METHODS: This study identified patients with age-related cataracts and divided them into two groups according to their anterior capsule and IOL optic relationship: total anterior capsule overlap (360°) and partial anterior capsule overlap (< 360°). Standard SS-OCT radial scanning was performed in all eyes at 1 day, 1 week, 1 month, and 3 months after cataract surgery, respectively. The obtained photographs were used for the postoperative position measurements of capsulorhexis and IOL after three-dimensional reconstruction.
RESULTS: This study included 46 eyes of 34 patients: total overlap group (n = 29) and partial overlap group (n = 17). The postoperative aqueous depth significantly decreased in the first week after surgery (P < .001). The IOL tilt was greater in the partial overlap group than that in the total overlap group (P = .014). The IOL moved significantly in the first week postoperatively (both P < .001). IOL decentration in the x-axis was greater in the partial overlap group than that in the total overlap group (P = .024). The IOL and capsulorhexis both moved sharply in the first week (both P < .05). The IOL moved consistently with the capsulorhexis in the 3 months after surgery (all P > .05).
CONCLUSIONS: The total overlap group showed better IOL centrality and stability. IOL movement may be driven by capsular bag contraction and fibrosis. Thus, it was demonstrated that postoperative IOL position and IOL performance were closely linked with proper size of central continuous curvilinear capsulorhexis. [J Refract Surg. 2020;36(6):388-394.]. Copyright 2020, SLACK Incorporated.

Entities:  

Mesh:

Year:  2020        PMID: 32521026     DOI: 10.3928/1081597X-20200420-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  3 in total

1.  Three-dimensional assessment of posterior capsule-intraocular lens interaction with and without primary posterior capsulorrhexis: an intraindividual randomized trial.

Authors:  Mengting Yu; Yue Huang; Yingbin Wang; Suzhen Xiao; Xinna Wu; Wenjie Wu
Journal:  Eye (Lond)       Date:  2021-10-23       Impact factor: 4.456

2.  Determining the Theoretical Effective Lens Position of Thick Intraocular Lenses for Machine Learning-Based IOL Power Calculation and Simulation.

Authors:  Damien Gatinel; Guillaume Debellemanière; Alain Saad; Mathieu Dubois; Radhika Rampat
Journal:  Transl Vis Sci Technol       Date:  2021-04-01       Impact factor: 3.283

Review 3.  Effect of Intraocular Lens Tilt and Decentration on Visual Acuity, Dysphotopsia and Wavefront Aberrations.

Authors:  Zahra Ashena; Sundas Maqsood; Syed Naqib Ahmed; Mayank A Nanavaty
Journal:  Vision (Basel)       Date:  2020-09-14
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.