Literature DB >> 32512544

Stability of flexible thin-film metallization stimulation electrodes: analysis of explants after first-in-human study and improvement of in vivo performance.

Paul Čvančara1, Tim Boretius, Víctor M López-Álvarez, Pawel Maciejasz, David Andreu, Stanisa Raspopovic, Francesco Petrini, Silvestro Micera, Giuseppe Granata, Eduardo Fernandez, Paolo M Rossini, Ken Yoshida, Winnie Jensen, Jean-Louis Divoux, David Guiraud, Xavier Navarro, Thomas Stieglitz.   

Abstract

OBJECTIVE: Micro-fabricated neural interfaces based on polyimide (PI) are achieving increasing importance in translational research. The ability to produce well-defined micro-structures with properties that include chemical inertness, mechanical flexibility and low water uptake are key advantages for these devices. APPROACH: This paper reports the development of the transverse intrafascicular multichannel electrode (TIME) used to deliver intraneural sensory feedback to an upper-limb amputee in combination with a sensorized hand prosthesis. A failure mode analysis on the explanted devices was performed after a first-in-human study limited to 30 d. MAIN
RESULTS: About 90% of the stimulation contact sites of the TIMEs maintained electrical functionality and stability during the full implant period. However, optical analysis post-explantation revealed that 62.5% of the stimulation contacts showed signs of delamination at the metallization-PI interface. Such damage likely occurred due to handling during explantation and subsequent analysis, since a significant change in impedance was not observed in vivo. Nevertheless, whereas device integrity is mandatory for long-term functionality in chronic implantation, measures to increase the bonding strength of the metallization-PI interface deserve further investigation. We report here that silicon carbide (SiC) is an effective adhesion-promoting layer resisting heavy electrical stimulation conditions within a rodent animal trial. Optical analysis of the new electrodes revealed that the metallization remained unaltered after delivering over 14 million pulses in vivo without signs of delamination at the metallization-PI interface. SIGNIFICANCE: Failure mode analysis guided implant stability optimization. Reliable adhesion of thin-film metallization to substrate has been proven using SiC, improving the potential transfer of micro-fabricated neural electrodes for chronic clinical applications. (Document number of Ethical Committee: P/905/CE/2012; Date of approval: 2012-10-04).

Entities:  

Mesh:

Year:  2020        PMID: 32512544     DOI: 10.1088/1741-2552/ab9a9a

Source DB:  PubMed          Journal:  J Neural Eng        ISSN: 1741-2552            Impact factor:   5.379


  7 in total

1.  The Materials Science Foundation Supporting the Microfabrication of Reliable Polyimide-Metal Neuroelectronic Interfaces.

Authors:  Cary A Kuliasha; Jack W Judy
Journal:  Adv Mater Technol       Date:  2021-05-03

2.  The Argo: a high channel count recording system for neural recording in vivo.

Authors:  Kunal Sahasrabuddhe; Aamir A Khan; Aditya P Singh; Tyler M Stern; Yeena Ng; Aleksandar Tadić; Peter Orel; Chris LaReau; Daniel Pouzzner; Kurtis Nishimura; Kevin M Boergens; Sashank Shivakumar; Matthew S Hopper; Bryan Kerr; Mina-Elraheb S Hanna; Robert J Edgington; Ingrid McNamara; Devin Fell; Peng Gao; Amir Babaie-Fishani; Sampsa Veijalainen; Alexander V Klekachev; Alison M Stuckey; Bert Luyssaert; Takashi D Y Kozai; Chong Xie; Vikash Gilja; Bart Dierickx; Yifan Kong; Malgorzata Straka; Harbaljit S Sohal; Matthew R Angle
Journal:  J Neural Eng       Date:  2021-02-24       Impact factor: 5.379

Review 3.  Toward higher-performance bionic limbs for wider clinical use.

Authors:  Dario Farina; Ivan Vujaklija; Rickard Brånemark; Anthony M J Bull; Hans Dietl; Bernhard Graimann; Levi J Hargrove; Klaus-Peter Hoffmann; He Helen Huang; Thorvaldur Ingvarsson; Hilmar Bragi Janusson; Kristleifur Kristjánsson; Todd Kuiken; Silvestro Micera; Thomas Stieglitz; Agnes Sturma; Dustin Tyler; Richard F Ff Weir; Oskar C Aszmann
Journal:  Nat Biomed Eng       Date:  2021-05-31       Impact factor: 25.671

4.  Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics.

Authors:  Alejandro Carnicer-Lombarte; Shao-Tuan Chen; George G Malliaras; Damiano G Barone
Journal:  Front Bioeng Biotechnol       Date:  2021-04-15

5.  A Subdural Bioelectronic Implant to Record Electrical Activity from the Spinal Cord in Freely Moving Rats.

Authors:  Bruce Harland; Zaid Aqrawe; Maria Vomero; Christian Boehler; Ernest Cheah; Brad Raos; Maria Asplund; Simon J O'Carroll; Darren Svirskis
Journal:  Adv Sci (Weinh)       Date:  2022-05-02       Impact factor: 17.521

6.  Numerical Evaluation on Residual Thermal Stress-Induced Delamination at PDMS-Metal Interface of Neural Prostheses.

Authors:  Yuyang Mao; Ivan Pechenizkiy; Thomas Stieglitz; Theodor Doll
Journal:  Micromachines (Basel)       Date:  2021-06-08       Impact factor: 2.891

7.  Biomedical Microtechnologies Beyond Scholarly Impact.

Authors:  Maria Vomero; Giuseppe Schiavone
Journal:  Micromachines (Basel)       Date:  2021-11-29       Impact factor: 2.891

  7 in total