A fast, green, sensitive, and accurate analytical method using high-performance liquid chromatography couple with fluorescence detection was established and validated for the simultaneous determination of amlodipine besylate and celecoxib in their recently approved fixed-dose combination tablets (1:20). Separation of the two drugs was achieved on C18 reversed-phase column (Thermo ODS Hypersil, 4.6 × 250 mm, particle size 5 µm) using acetonitrile:potassium phosphate buffer (50 mM; pH 5.5, 60:40 v/v) as a mobile phase at 40°C, which eluted at a rate of 1 mL/min. Detection was carried out with excitation and emission wavelengths of 360 and 446 nm for amlodipine and 265 and 359 nm for celecoxib, respectively. The method was linear over a concentration range of 0.05-2 and 0.05-10 µg/mL and limit of detection reached to 0.017 and 0.0167 µg/mL for amlodipine and celecoxib, respectively. The developed method was successfully applied to assess the cited drugs in their newly FDA approved fixed-dose combination tablet dosage form. Furthermore, the method was found to be sensitive and eco-friendly green alternative to the reported methods as it was evaluated according to the green analytical procedure index tool guidelines and analytical Eco-Scale.Entities:
Keywords: amlodipine; celecoxib; eco-friendly; fluorescence detection; liquid chromatography
Mesh:
Substances:
Year: 2020 PMID: 32506818 DOI: 10.1002/jssc.202000345
Source DB: PubMed Journal: J Sep Sci ISSN: 1615-9306 Impact factor: 3.645