| Literature DB >> 32505211 |
Xianyong Li1, Changsong Wang1, Shengjie Kou2, Peiyao Luo1, Mingyan Zhao3, Kaijiang Yu4.
Abstract
Entities:
Keywords: Lung ventilation function; Restriction ventilation dysfunction; Severe COVID-19; Small airway dysfunction
Mesh:
Year: 2020 PMID: 32505211 PMCID: PMC7275849 DOI: 10.1186/s13054-020-02992-6
Source DB: PubMed Journal: Crit Care ISSN: 1364-8535 Impact factor: 9.097
Lung ventilation function type and variable values for the 18 severe COVID-19 patients
| First | Second | ||
|---|---|---|---|
| Normal | 8 | 8 | > 0.05 |
| Obstructive ventilation dysfunction | 1 | 1 | |
| Restriction ventilation dysfunction | 4 | 3 | |
| Small airway dysfunction | 3 | 4 | |
| Restriction ventilation dysfunction with small airway dysfunction | 2 | 2 | |
| VC/predicted value, % | 82.8 ± 15.9 | 88.8 ± 16.5 | < 0.01 |
| FVC predicted value, % | 84.1 ± 15.4 | 91.5 ± 17.3 | < 0.01 |
| FEV1/predicted value, % | 84.5 ± 16.3 | 89.4 ± 15.7 | < 0.01 |
| FEV1/FVC, % | 85.2 ± 6.1 | 80.5 ± 7.0 | < 0.05 |
| MMEF/predicted value, % | 77.9 ± 27.9 | 73.6 ± 29.8 | > 0.05 |