Literature DB >> 32504276

Low-cost Fluorescein as an Alternative to Radio-colloid for Sentinel Lymph Node Biopsy-a Prospective Validation Study in Early Breast Cancer.

Ramya C Valiveru1, Gaurav Agarwal2, Vinita Agrawal3, Sanjay Gambhir4, Sabaretnam Mayilvaganan1, Gyan Chand1, Anjali Mishra1, Amit Agarwal1, Saroj K Mishra1.   

Abstract

BACKGROUND: Sentinel lymph node biopsy (SLNB) using radio-pharmaceutical (RP) and a blue dye is gold standard for axillary staging in clinically node-negative early breast cancer. High costs and limited availability of RP and/or gamma probe are major deterrents in performing SLNB in developing countries. Fluorescence-guided SLNB can obviate the need for RP and gamma probe. Fluorescein is an inexpensive fluorescent lymphatic tracer. In this study, we compared SLN identification rate (SLN-IR) and false negative rates (FNR) of fluorescein-guided SLNB and radio-guided SLNB using 99mTc-Sulfur-colloid, in isolation, or in combination with methylene blue dye (MBD).
METHODS: Sixty-five cN0 early and large operable breast cancer patients underwent validation SLNB using fluorescein (and blue LED light), 99mTc-Sulfur-colloid (and gamma probe) and MBD. Inj Fluorescein 4% was injected, 1 ml each peri-tumoral and sub-areolar five minutes before axillary incision. Axillary dissection was performed irrespective of SLNB histology. The SLN-IR and FNR with various tracers and their combinations were compared.
RESULTS: The mean number of SLNs identified was 3.5 ± 1.8 (range 1-6). The SLN-IR using RP alone was 94%, fluorescein alone was 92%, and MBD alone was 82%. The SLN-IR using fluorescein plus MBD combination was 95.4%, compared to 97% using MBD plus RP combination. FNR was 6.3% using fluorescein plus MBD, as well as RP plus MBD combinations.
CONCLUSIONS: SLN-IR of > 90% and SLN-FNR of < 10% using fluorescein plus MBD combination are in acceptable range, and are comparable to that of RP plus MBD combination. Fluorescein can replace RP for performing SLNB, in combination with MBD.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32504276     DOI: 10.1007/s00268-020-05631-x

Source DB:  PubMed          Journal:  World J Surg        ISSN: 0364-2313            Impact factor:   3.352


  3 in total

1.  Validation sentinel lymph node biopsy study in cN0 axilla using low-cost dual dye technique: potential solution for resource poor settings.

Authors:  Jayesh Chavda; Arpan Mishra; Ashutosh Silodia; Sanjay Kumar Yadav; Deepti Bala Sharma; Dhananjaya Sharma; Muktesh Khandare
Journal:  Breast Cancer Res Treat       Date:  2022-03-05       Impact factor: 4.872

2.  Comparison of two different surgical strategies for breast cancer patients treated with mastectomy plus sentinel lymph node biopsy.

Authors:  Xing Zhang; Qian Shen; Yu-Jie Hu
Journal:  Updates Surg       Date:  2021-06-10

Review 3.  The current status and future prospects for molecular imaging-guided precision surgery.

Authors:  Imke Boekestijn; Matthias N van Oosterom; Paolo Dell'Oglio; Floris H P van Velden; Martin Pool; Tobias Maurer; Daphne D D Rietbergen; Tessa Buckle; Fijs W B van Leeuwen
Journal:  Cancer Imaging       Date:  2022-09-06       Impact factor: 5.605

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.