Literature DB >> 32497762

Comparison of left ventricular lead upgrade vs continued medical care among patients eligible for cardiac resynchronization therapy at the time of defibrillator generator replacement: Predictors of left ventricular lead upgrade and associations with long-term outcomes.

Matthew C Hyman1, Haikun Bao2, Jeptha P Curtis2, Karl Minges2, Robert D Schaller1, Ulrika Birgersdotter-Green3, Francis E Marchlinski1, Jonathan C Hsu4.   

Abstract

BACKGROUND: Randomized trials evaluating cardiac resynchronization therapy (CRT) have excluded patients with a pre-existing implantable cardioverter-defibrillator (ICD). The association of CRT upgrade with clinical outcomes in patients with a pre-existing ICD is unclear.
OBJECTIVE: The purpose of this study was to examine a CRT-eligible population to evaluate clinical outcomes associated with CRT upgrade compared to patients who did not undergo CRT.
METHODS: Using the National Cardiovascular Data Registry (NCDR) ICD Registry between April 2010 and December 2014, we created a hierarchical logistic regression model to identify predictors of CRT upgrade in a CRT-eligible ICD population. In the subpopulation of patients with Medicare-linked claims data, differential outcomes were determined with censoring at 3 years. The primary endpoint of this study was all-cause mortality, with secondary endpoints of rates of hospitalization and procedural complications.
RESULTS: CRT upgrade was performed in 75.5% of CRT-eligible patients with pre-existing ICD (n = 15,803). Presence of left bundle branch block conduction was the strongest predictor of CRT upgrade (odds ratio [OR] 4.56; 95% confidence interval [CI] 4.08-5.11; P <.0001). In both unadjusted and adjusted analyses, CRT upgrade was associated with a reduction in mortality at 3 years (unadjusted hazard ratio [HR] 0.80; 95% CI 0.70-0.92; P = .001; adjusted HR 0.84; 95% CI 0.72-0.98; P = .02, respectively). Compared to patients with ICD generator replacement only, patients who underwent CRT upgrade experienced no different 3-year rates of hospitalization (adjusted HR 1.01; 95% CI 0.91-1.12; P = .81) or 1-year periprocedural complication rates (adjusted HR 1.07; 95% CI 0.79-1.45; P = .66).
CONCLUSION: In a national registry of CRT-eligible patients with pre-existing ICD, upgrade to CRT was associated with lower rates of mortality than continued medical management.
Copyright © 2020 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Adverse events; Cardiac resynchronization therapy; Generator replacement; Implantable-cardioverter defibrillator; Mortality

Year:  2020        PMID: 32497762     DOI: 10.1016/j.hrthm.2020.05.032

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  1 in total

1.  Long-term clinical outcomes after upgrade to resynchronization therapy: A propensity score-matched analysis.

Authors:  Mariana Brandão; João Gonçalves Almeida; Paulo Fonseca; Joel Monteiro; Elisabeth Santos; Filipa Rosas; José Nogueira Ribeiro; Marco Oliveira; Helena Gonçalves; João Primo; Ricardo Fontes-Carvalho
Journal:  Heart Rhythm O2       Date:  2021-12-17
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.