Literature DB >> 32485426

Verification of reliability and validity of motion analysis systems during bilateral squat using human pose tracking algorithm.

Megumi Ota1, Hiroshige Tateuchi2, Takaya Hashiguchi3, Takehiro Kato4, Yasuhiro Ogino3, Momoko Yamagata4, Noriaki Ichihashi4.   

Abstract

BACKGROUND: The human tracking algorithm called OpenPose can detect joint points and calculate joint angles. However, the reliability and validity of OpenPose have not been clarified yet. RESEARCH QUESTION: Are there the enough reliability and validity of OpenPose based motion analysis?
METHODS: 20 healthy young subjects participated in this study. The motion task was a bilateral squat. The joint angles of the trunk, hip, knee, and ankle were calculated using OpenPose and VICON. Kinematic measurements by three-dimensional motion analysis devices were recorded using VICON. Simultaneously, the images were taken with a digital camera from the right side. After the images were processed with OpenPose, joint angles were calculated from estimated joint points. To confirm the test-retest reliability within device, intraclass correlation coefficients [ICC (1, 3)] were calculated. To confirm the validity, linear regression analysis and ICC (2, 1) between the data obtained by OpenPose and VICON were calculated. Furthermore, the agreement between the data obtained by OpenPose and VICON was assessed by Bland-Altman analysis.
RESULTS: ICCs (1, 3) of the data obtained by OpenPose and VICON were almost perfect. There were significant associations between the data obtained by OpenPose and VICON. ICCs (2, 1) between the data obtained by OpenPose and VICON were almost perfect or substantial for trunk, knee and ankle joints, and fair on the hip joint. There were fixed biases on knee and ankle joints, and proportional biases on trunk and hip joint. SIGNIFICANCE: OpenPose based motion analysis is reliable and has the advantage of being low cost and easier to operate than conventional methods. In future, to consider the clinical utility of OpenPose, it is necessary to identify the error between the true values indicating actual joint movement and data obtained by OpenPose with its correction for fixed and proportional biases. (295 words).
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Human pose tracking algorithm; Motion analysis; OpenPose

Mesh:

Year:  2020        PMID: 32485426     DOI: 10.1016/j.gaitpost.2020.05.027

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  5 in total

1.  Assessing Stability of Crutch Users by Non-Contact Methods.

Authors:  Achilles Vairis; Suzana Brown; Maurice Bess; Kyu Hyun Bae; Jonathan Boyack
Journal:  Int J Environ Res Public Health       Date:  2021-03-15       Impact factor: 3.390

2.  Automatic Markerless Motion Detector Method against Traditional Digitisation for 3-Dimensional Movement Kinematic Analysis of Ball Kicking in Soccer Field Context.

Authors:  Luiz H Palucci Vieira; Paulo R P Santiago; Allan Pinto; Rodrigo Aquino; Ricardo da S Torres; Fabio A Barbieri
Journal:  Int J Environ Res Public Health       Date:  2022-01-21       Impact factor: 3.390

Review 3.  Applications of Pose Estimation in Human Health and Performance across the Lifespan.

Authors:  Jan Stenum; Kendra M Cherry-Allen; Connor O Pyles; Rachel D Reetzke; Michael F Vignos; Ryan T Roemmich
Journal:  Sensors (Basel)       Date:  2021-11-03       Impact factor: 3.576

4.  The reliability and validity of gait analysis system using 3D markerless pose estimation algorithms.

Authors:  Shengyun Liang; Yu Zhang; Yanan Diao; Guanglin Li; Guoru Zhao
Journal:  Front Bioeng Biotechnol       Date:  2022-08-10

5.  Reliability of a human pose tracking algorithm for measuring upper limb joints: comparison with photography-based goniometry.

Authors:  Jingyuan Fan; Fanbin Gu; Lulu Lv; Zhejin Zhang; Changbing Zhu; Jian Qi; Honggang Wang; Xiaolin Liu; Jiantao Yang; Qingtang Zhu
Journal:  BMC Musculoskelet Disord       Date:  2022-09-21       Impact factor: 2.562

  5 in total