Abstract

Early identification of kidney function deterioration is essential to determine which newborn patients with dilation of the renal pelvis (hydronephrosis) should undergo surgery. Kidney function can be measured by fitting a tracer kinetic (TK) model onto a series of Dynamic Contrast Enhanced (DCE) MR images and deriving the glomerular filtration rate (GFR) from the TK model. Unfortunately, heavy breathing and large bulk motion events create outliers and misalignments that introduce large errors in the TK estimates. Moreover, aligning the series of DCE images is not trivial due to the contrast differences between them and the undersampling artifacts due to fast imaging. We present a bulk motion detection and a linear time invariant (LTI) model-based motion correction approach for DCE-MRI alignment that leverages the temporal dynamics of the DCE data at each voxel. We evaluate our approach on 10 newborn patients that underwent DCE imaging without sedation. For each patient, we reconstructed the sequence of DCE images, detected and removed the volumes corrupted by motion using a self navigation approach, aligned the sequence using our approach and fitted the TK model to compute GFR. The results show that our approach correctly aligned all volumes and improved the TK model fit and, on average, reducing the normalized root-mean-squared error by 0.17.

Entities:  

Keywords:  Another keyword; First keyword; Second keyword

Year:  2019        PMID: 32483560      PMCID: PMC7262873          DOI: 10.1007/978-3-030-32245-8_48

Source DB:  PubMed          Journal:  Med Image Comput Comput Assist Interv


  6 in total

1.  PCA-based groupwise image registration for quantitative MRI.

Authors:  W Huizinga; D H J Poot; J-M Guyader; R Klaassen; B F Coolen; M van Kranenburg; R J M van Geuns; A Uitterdijk; M Polfliet; J Vandemeulebroucke; A Leemans; W J Niessen; S Klein
Journal:  Med Image Anal       Date:  2015-12-19       Impact factor: 8.545

2.  Tracer kinetic model-driven registration for dynamic contrast-enhanced MRI time-series data.

Authors:  Giovanni A Buonaccorsi; James P B O'Connor; Angela Caunce; Caleb Roberts; Sue Cheung; Yvonne Watson; Karen Davies; Lynn Hope; Alan Jackson; Gordon C Jayson; Geoffrey J M Parker
Journal:  Magn Reson Med       Date:  2007-11       Impact factor: 4.668

3.  elastix: a toolbox for intensity-based medical image registration.

Authors:  Stefan Klein; Marius Staring; Keelin Murphy; Max A Viergever; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2009-11-17       Impact factor: 10.048

4.  Motion-robust parameter estimation in abdominal diffusion-weighted MRI by simultaneous image registration and model estimation.

Authors:  Sila Kurugol; Moti Freiman; Onur Afacan; Liran Domachevsky; Jeannette M Perez-Rossello; Michael J Callahan; Simon K Warfield
Journal:  Med Image Anal       Date:  2017-05-03       Impact factor: 8.545

5.  MRI-measurement of perfusion and glomerular filtration in the human kidney with a separable compartment model.

Authors:  Steven P Sourbron; Henrik J Michaely; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Invest Radiol       Date:  2008-01       Impact factor: 6.016

6.  Golden-angle radial sparse parallel MRI: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI.

Authors:  Li Feng; Robert Grimm; Kai Tobias Block; Hersh Chandarana; Sungheon Kim; Jian Xu; Leon Axel; Daniel K Sodickson; Ricardo Otazo
Journal:  Magn Reson Med       Date:  2013-10-18       Impact factor: 4.668

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.