Literature DB >> 32483043

Automated Dicentric Aberration Scoring for Triage Dose Assessment: 60Co Gamma Ray Dose-response at Different Dose Rates.

Uma Subramanian1, Brett O'Brien1, Maureen McNamara1, Lyudmila Romanyukha1, David L Bolduc1, Cara Olsen2, William F Blakely1.   

Abstract

The objective of this study was to establish radiation dose-response calibration curves using automated dicentric scoring to support rapid and accurate cytogenetic triage dose-assessment. Blood was drawn from healthy human volunteers and exposed to Co gamma rays at several dose rates (i.e., 1.0, 0.6, and 0.1 Gy min). After radiation, the blood was placed for 2 h in a 37 °C incubator for repair. Blood was then cultured in complete media to which a mitogen (i.e., phytoghemagglutinin, concentration 4%) was added for 48 h. Colcemid was added to the culture at a final concentration of 0.2 μg mL after 24 h for the purpose of arresting first-division metaphase mitotics. Cells were harvested at the end of 48 h. Samples were processed using an automated metaphase harvester and automated microscope metaphase finder equipped with a suite of software including a specialized automated dicentric scoring application. The data obtained were used to create dose-response tables of dicentric yields. The null hypothesis that the data is Poisson-distributed could not be rejected at the significance level of α = 0.05 using results from a Shiny R Studio application (goodness-of-fit Poisson). Calibration curves based on linear-quadratic fits for Co gamma rays at the three different dose rates were generated using these data. The calibration curves were used to detect blind test cases. In conclusion, using the automated harvester and automated microscope metaphase finder with associated automated dicentric scoring software demonstrates high-throughput with suitable accuracy for triage radiation dose assessment.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 32483043     DOI: 10.1097/HP.0000000000001285

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  3 in total

1.  Metaphase Cells Enrichment for Efficient Use in the Dicentric Chromosome Assay.

Authors:  Max Platkov; Uzi Hadad; Ariela Burg; Inna Levitsky; Michael Zagatzki; Omer Damri; Aryeh Weiss; Yair Lauber; Shirly Amar; Lior Carmel; Raphael Gonen
Journal:  Cell Biochem Biophys       Date:  2022-10-11       Impact factor: 2.989

2.  Establishing a Reference Dose-Response Calibration Curve for Dicentric Chromosome Aberrations to Assess Accidental Radiation Exposure in Saudi Arabia.

Authors:  Ghazi A Alsbeih; Khaled S Al-Hadyan; Najla M Al-Harbi; Sara S Bin Judia; Belal A Moftah
Journal:  Front Public Health       Date:  2020-12-15

3.  Comparison and Evaluation of Different Radiotherapy Techniques Using Biodosimetry Based on Cytogenetics.

Authors:  Aggeliki Nikolakopoulou; Vasiliki Peppa; Antigoni Alexiou; George Pissakas; Georgia Terzoudi; Pantelis Karaiskos
Journal:  Cancers (Basel)       Date:  2021-12-29       Impact factor: 6.639

  3 in total