Literature DB >> 3248129

Is dialysis hypotension caused by an abnormality of venous tone?

J R Bradley1, D B Evans, S M Gore, A J Cowley.   

Abstract

The role of peripheral vascular tone in the development of hypotension induced by dialysis was investigated in eight patients undergoing haemodialysis with acetate or bicarbonate buffered fluid. Each patient had two sessions of dialysis with acetate fluid and two with bicarbonate fluid in the order acetate, bicarbonate, bicarbonate, acetate or bicarbonate, acetate, acetate, bicarbonate. Mean arterial blood pressure fell at a mean rate of 3.9 mm Hg/hour during dialysis with acetate fluid and 1.4 mm Hg/hour during dialysis with bicarbonate fluid. The rate of fall was significantly greater during dialysis with acetate fluid compared with bicarbonate fluid. Heart rate increased by a mean rate of 2.6 beats/min/hour during dialysis with both acetate and bicarbonate fluid. Vascular resistance in the forearm increased at a rate of 3.6 units/hour during dialysis with acetate fluid and 4.5 units/hour during dialysis with bicarbonate fluid, but the venous bed of the forearm dilated. The index of venous tone rose at a mean rate of 0.23 ml/dl [corrected] over 40 mm Hg/hour during dialysis with acetate fluid and 0.20 ml/dl over 40 mm Hg/hour during dialysis with bicarbonate fluid. Inappropriate peripheral venodilatation may be important in the development of hypotension induced by dialysis.

Entities:  

Mesh:

Year:  1988        PMID: 3248129      PMCID: PMC2546161          DOI: 10.1136/bmj.296.6637.1634

Source DB:  PubMed          Journal:  Br Med J (Clin Res Ed)        ISSN: 0267-0623


  5 in total

Review 1.  Reflex control of the peripheral circulation.

Authors:  F M Abboud; D D Heistad; A L Mark; P G Schmid
Journal:  Prog Cardiovasc Dis       Date:  1976 Mar-Apr       Impact factor: 8.194

Review 2.  Hemodynamic instability during hemodialysis.

Authors:  W L Henrich
Journal:  Kidney Int       Date:  1986-10       Impact factor: 10.612

3.  Acetate or bicarbonate for haemodialysis?

Authors:  M A Mansell; A J Wing
Journal:  Br Med J (Clin Res Ed)       Date:  1983-07-30

4.  Hemodynamic study of hypotension during hemodialysis.

Authors:  J P Kinet; D Soyeur; N Balland; M Saint-Remy; P Collignon; J P Godon
Journal:  Kidney Int       Date:  1982-06       Impact factor: 10.612

5.  Bicarbonate hemodialysis: influence on plasma refilling and hemodynamic stability.

Authors:  C H Hsu; R D Swartz; M G Somermeyer; A Raj
Journal:  Nephron       Date:  1984       Impact factor: 2.847

  5 in total
  3 in total

1.  Analysis of serial measurements in medical research.

Authors:  J N Matthews; D G Altman; M J Campbell; P Royston
Journal:  BMJ       Date:  1990-01-27

2.  Comparison of vascular tone during combined haemodialysis with ultrafiltration and during ultrafiltration followed by haemodialysis: a possible mechanism for dialysis hypotension.

Authors:  J R Bradley; D B Evans; A J Cowley
Journal:  BMJ       Date:  1990-05-19

3.  Effects of the intermittent pneumatic circulator on blood pressure during hemodialysis.

Authors:  Tzu-Chao Hsu; Ya-Ju Chang; Yu-Yao Huang; Miao-Ju Hsu
Journal:  Sensors (Basel)       Date:  2010-11-09       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.