A Snapshot of the Prevalence and Molecular Diversity of Legionella pneumophila in the Water Systems of Israeli Hotels.

Eugenia Yakunin1, Eszter Kostyal2, Vered Agmon1, Itamar Grotto1,3, Lea Valinsky1, Jacob Moran-Gilad1,3.   

Abstract

Exposure to Legionella spp. contaminated aerosols in hotel settings confers risk for travel-associated Legionnaire's disease (TALD). In this study, we investigated the prevalence of Legionella contamination and its molecular diversity in hotels and resorts across Israel. The study was comprised of a convenience sample of water systems from 168 hotels and resorts countrywide, routinely inspected between March 2015 and February 2017. Isolation and quantitation of Legionella were performed in a water laboratory using the ISO 11731 method. The distribution of Legionella isolates was analyzed according to geography and source. The genetic diversity of a subset of isolates was analyzed by sequence-based typing (SBT) at the National Reference Laboratory for Legionella and compared to the national database. Out of 2830 samples tested, 470 (17%) obtained from 102 different premises (60% of hotels) were positive for Legionella spp. In 230 samples (49% of all positive, 8% of total samples), accounting for 37% of hotels, Legionella spp. counts exceeded the regulatory threshold of 1000 CFU/L. The most frequently contaminated water sources were cooling towers (38%), followed by faucets, hot tubs, water lines, and storage tanks (14%-17% each). Furthermore, 32% and 17% of samples obtained from cooling towers and hot tubs, respectively, exceeded the regulatory thresholds. SBT was performed on 78 strains and revealed 27 different sequence types (STs), including two novel STs. The most prevalent STs found were ST1 (26%), ST87 (10%), ST93 (6%), and ST461 and ST1516 (5% each). Several L. pneumophila STs were found to be limited to certain geographical regions. This is the first study to investigate the prevalence and diversity of Legionella in hotels and resorts in Israel during non-outbreak environmental inspections. These findings will inform risk assessment, surveillance, and control measures of TALD.

Entities:  

Keywords:  Legionella pneumophila; SBT; hotels; molecular diversity

Year:  2020        PMID: 32471136     DOI: 10.3390/pathogens9060414

Source DB:  PubMed          Journal:  Pathogens        ISSN: 2076-0817


  3 in total

Review 1.  Legionella and Biofilms-Integrated Surveillance to Bridge Science and Real-Field Demands.

Authors:  Ana Pereira; Ana Rosa Silva; Luis F Melo
Journal:  Microorganisms       Date:  2021-06-03

2.  Assessing Hotel Employee Knowledge on Risk Factors and Risk Management Procedures for Microbial Contamination of Hotel Water Distribution Systems.

Authors:  Brandon Leftwich; Samuel Opoku; Jingjing Yin; Atin Adhikari
Journal:  Int J Environ Res Public Health       Date:  2021-03-29       Impact factor: 3.390

3.  Occurrence of Legionella spp. in Man-Made Water Sources: Isolates Distribution and Phylogenetic Characterization in the Emilia-Romagna Region.

Authors:  Marta Mazzotta; Silvano Salaris; Maria Rosaria Pascale; Luna Girolamini; Sandra Cristino
Journal:  Pathogens       Date:  2021-05-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.