Literature DB >> 32470927

Three-dimensional assessment of robot-assisted pedicle screw placement accuracy and instrumentation reliability based on a preplanned trajectory.

Bowen Jiang1, Zach Pennington1, Alex Zhu1, Stavros Matsoukas2, A Karim Ahmed1, Jeff Ehresman1, Smruti Mahapatra3, Ethan Cottrill1, Hailey Sheppell3, Amir Manbachi3, Neil Crawford4, Nicholas Theodore1.   

Abstract

OBJECTIVE: Robotic spine surgery systems are increasingly used in the US market. As this technology gains traction, however, it is necessary to identify mechanisms that assess its effectiveness and allow for its continued improvement. One such mechanism is the development of a new 3D grading system that can serve as the foundation for error-based learning in robot systems. Herein the authors attempted 1) to define a system of providing accuracy data along all three pedicle screw placement axes, that is, cephalocaudal, mediolateral, and screw long axes; and 2) to use the grading system to evaluate the mean accuracy of thoracolumbar pedicle screws placed using a single commercially available robotic system.
METHODS: The authors retrospectively reviewed a prospectively maintained, IRB-approved database of patients at a single tertiary care center who had undergone instrumented fusion of the thoracic or lumbosacral spine using robotic assistance. Patients with preoperatively planned screw trajectories and postoperative CT studies were included in the final analysis. Screw accuracy was measured as the net deviation of the planned trajectory from the actual screw trajectory in the mediolateral, cephalocaudal, and screw long axes.
RESULTS: The authors identified 47 patients, 51% male, whose pedicles had been instrumented with a total of 254 screws (63 thoracic, 191 lumbosacral). The patients had a mean age of 61.1 years and a mean BMI of 30.0 kg/m2. The mean screw tip accuracies were 1.3 ± 1.3 mm, 1.2 ± 1.1 mm, and 2.6 ± 2.2 mm in the mediolateral, cephalocaudal, and screw long axes, respectively, for a net linear deviation of 3.6 ± 2.3 mm and net angular deviation of 3.6° ± 2.8°. According to the Gertzbein-Robbins grading system, 184 screws (72%) were classified as grade A and 70 screws (28%) as grade B. Placement of 100% of the screws was clinically acceptable.
CONCLUSIONS: The accuracy of the discussed robotic spine system is similar to that described for other surgical systems. Additionally, the authors outline a new method of grading screw placement accuracy that measures deviation in all three relevant axes. This grading system could provide the error signal necessary for unsupervised machine learning by robotic systems, which would in turn support continued improvement in instrumentation placement accuracy.

Entities:  

Keywords:  pedicle screw accuracy; robot assistance; surgical technique; three-dimensional accuracy

Year:  2020        PMID: 32470927     DOI: 10.3171/2020.3.SPINE20208

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  5 in total

Review 1.  Augmented Reality in Spine Surgery: A Narrative Review.

Authors:  Andrew Hersh; Smruti Mahapatra; Carly Weber-Levine; Tolulope Awosika; John N Theodore; Hesham M Zakaria; Ann Liu; Timothy F Witham; Nicholas Theodore
Journal:  HSS J       Date:  2021-07-14

2.  Robotic-Navigated Percutaneous Pedicle Screw Placement Has Less Facet Joint Violation Than Fluoroscopy-Guided Percutaneous Screws.

Authors:  Gennadiy A Katsevman; Raven D Spencer; Scott D Daffner; Sanjay Bhatia; Robert A Marsh; John C France; Shari Cui; Patricia Dekeseredy; Cara L Sedney
Journal:  World Neurosurg       Date:  2021-05-04       Impact factor: 2.210

3.  Pearls and pitfalls of posterior superior iliac spine reference frame placement for spinal navigation: cadaveric series.

Authors:  Brendan F Judy; Hector Soriano-Baron; Yike Jin; Hesham M Zakaria; Srujan Kopparapu; Mir Hussain; Connor Pratt; Nicholas Theodore
Journal:  J Neurosurg Case Lessons       Date:  2022-02-28

4.  Can Postoperative CT Imaging in Spine Surgery Be Replaced by Intraoperative 3D Rotation With the C-Arm?: Results of a Prospective Single Center Cohort Study.

Authors:  Mohammed Banat; Johannes Wach; Abdallah Salemdawod; Lisa Domurath; Jasmin Scorzin; Hartmut Vatter
Journal:  Front Surg       Date:  2021-07-14

5.  Initial Intraoperative Experience with Robotic-Assisted Pedicle Screw Placement with Cirq® Robotic Alignment: An Evaluation of the First 70 Screws.

Authors:  Mirza Pojskić; Miriam Bopp; Christopher Nimsky; Barbara Carl; Benjamin Saβ
Journal:  J Clin Med       Date:  2021-12-07       Impact factor: 4.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.