Literature DB >> 32468863

Microneedle ocular patch: fabrication, characterization, and ex-vivo evaluation using pilocarpine as model drug.

Girdhari Roy1, Rohini Devi Galigama1, Veda Suresh Thorat1, Prashant Garg2, Venkata Vamsi Krishna Venuganti1.   

Abstract

Context: Enhacing the ocular bioavailability of drugs after their topical application is a challenge.Objective: The objective of the study was to design, fabricate, and investigate the effectiveness of microneedle ocular patch (MOP) in delivering the model drug, pilocarpine HCl across the corneal membrane.
Methods: MOP mimicked commercially available contact lens design elements having a diameter of 14.20 mm and a sagittal height of 3.85 mm with a convex curvature. The base of this patch contained an array of 25 pyramid-shaped microneedles measuring 521 ± 10 µm in length. Pilocarpine loaded MOP was prepared by micromolding technique using dissolvable polyvinyl alcohol and polyvinyl pyrrolidone matrix. MOP was characterized for physical and mechanical properties using a stereomicroscope, scanning electron microscope, and texture analyzer.
Results: Histological examination after MOP application on excised human cornea showed penetration of microneedles with a required insertional force of 1.04 ± 0.17 N. Flux of pilocarpine across excised cornea was significantly (p < 0.05) greater after application of MOP (704 ± 149 µg/cm2/h) compared with solution formulation (188 ± 24 µg/cm2/h). Ex-vivo pilocarpine permeation study in porcine eye globe revealed significantly (p < 0.05) greater availability in aqueous humor within 30 min of application of MOP (249 ± 85 µg/ml) compared with solution formulation (46 ± 9 µg/ml).
Conclusion: MOP can be developed as a potential ophthalmic drug delivery system.

Entities:  

Keywords:  Microneedle ocular patch; corneal permeation; flux; micromolding; pilocarpine

Mesh:

Substances:

Year:  2020        PMID: 32468863     DOI: 10.1080/03639045.2020.1776317

Source DB:  PubMed          Journal:  Drug Dev Ind Pharm        ISSN: 0363-9045            Impact factor:   3.225


  4 in total

Review 1.  Potential of Microneedle Systems for COVID-19 Vaccination: Current Trends and Challenges.

Authors:  Jasmin Hassan; Charlotte Haigh; Tanvir Ahmed; Md Jasim Uddin; Diganta B Das
Journal:  Pharmaceutics       Date:  2022-05-16       Impact factor: 6.525

2.  Stereomicroscope with Imaging Analysis: A Versatile Tool for Wetting, Gel Formation and Erosion Rate Determinations of Eutectic Effervescent Tablet.

Authors:  Pornsit Chaiya; Siriporn Okonogi; Thawatchai Phaechamud
Journal:  Pharmaceutics       Date:  2022-06-16       Impact factor: 6.525

Review 3.  The Finite Element Analysis Research on Microneedle Design Strategy and Transdermal Drug Delivery System.

Authors:  Qinying Yan; Shulin Shen; Yan Wang; Jiaqi Weng; Aiqun Wan; Gensheng Yang; Lili Feng
Journal:  Pharmaceutics       Date:  2022-08-03       Impact factor: 6.525

4.  Rapidly dissolving microneedle patch of amphotericin B for intracorneal fungal infections.

Authors:  Alyaa A Albadr; Ismaiel A Tekko; Lalitkumar K Vora; Ahlam A Ali; Garry Laverty; Ryan F Donnelly; Raghu Raj Singh Thakur
Journal:  Drug Deliv Transl Res       Date:  2021-07-23       Impact factor: 4.617

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.