Literature DB >> 32466876

Biomechanical comparison of suture-button, bioabsorbable screw, and metal screw for ankle syndesmotic repair: A meta-analysis.

Joseph S Lee1, Bryan Curnutte1, Karen Pan1, Jiayong Liu2, Nabil A Ebraheim1.   

Abstract

BACKGROUND: To compare biomechanically metal screw fixation to suture-button or bioabsorbable screw fixation for ankle syndesmotic injuries.
METHODS: A literature search of the comparison studies in Pubmed and Google Scholar was conducted. The biomechanical outcomes of interest were syndesmotic stability in the coronal, sagittal, and axial planes as well as torque and rotation at failure.
RESULTS: A total of 11 cadaveric studies were included. In the suture-button group, coronal displacement (MD 1.72mm, p = 0.02) and sagittal displacement (MD 2.65mm, p = 0.0003) were increased relative to the metal screw group. In contrast, no difference was found with axial rotation (MD 0.35 degrees, p = 0.57). Bioabsorbable screws exhibited equivalent failure torque (MD -3.04Nm, p = 0.53) and rotation at failure (MD 3.77 degrees, p = 0.48) in comparison to metal screws.
CONCLUSIONS: Suture-button provide less rigidity when compared to metal screw fixation. They afford flexible syndesmotic micromotion which may more closely resemble a physiological state and be helpful for ligament healing. Bioabsorbable screws demonstrate similar mechanical strength properties to metal screws.
Copyright © 2020 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bioabsorbable syndesmotic screw; Biomechanical; Metal syndesmotic screw; Suture button syndesmosis; Syndesmotic ankle injuries; TightRope

Mesh:

Year:  2020        PMID: 32466876     DOI: 10.1016/j.fas.2020.03.008

Source DB:  PubMed          Journal:  Foot Ankle Surg        ISSN: 1268-7731            Impact factor:   2.705


  3 in total

1.  Minimally Invasive Percutaneous TightRope® System Fixation for an Unstable Posterior Pelvic Ring: Clinical Follow-up and Biomechanical Studies.

Authors:  Feng Gu; Jiting Zhang; Zhenjiang Sui; Ke Zhang; Xiaoping Xie; Tiecheng Yu
Journal:  Orthop Surg       Date:  2022-04-26       Impact factor: 2.279

Review 2.  A systematic review of ankle fracture-dislocations: Recent update and future prospects.

Authors:  Mu-Min Cao; Yuan-Wei Zhang; Sheng-Ye Hu; Yun-Feng Rui
Journal:  Front Surg       Date:  2022-08-09

Review 3.  Ankle and syndesmosis instability: consensus and controversies.

Authors:  Nuno Corte-Real; João Caetano
Journal:  EFORT Open Rev       Date:  2021-06-28
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.