Characterisation of blink dynamics using a high-speed infrared imaging system.

Maria Navascues-Cornago1, Philip B Morgan1, Carole Maldonado-Codina1, Michael L Read1.   

Abstract

PURPOSE: Development and validation of a non-invasive imaging system to capture spontaneous blinking and characterise blink dynamics using a custom image analysis algorithm.
METHODS: A pilot study investigated the influence of illumination type on blink dynamics. Spontaneous blinking was recorded in eight subjects using a high-speed camera under two illumination conditions: white light and infrared. Custom semi-automated software assessed palpebral aperture height (PAH), blink rate, blink speed, blink completeness and blink duration. The main clinical study compared two different image analysis techniques. Spontaneous blinking was recorded in 20 subjects using a high-speed infrared camera. Blink speed and duration were determined using two techniques: manual tracking and semi-automated tracking. Agreement between the two techniques was assessed using Bland-Altman analysis. Coefficients of repeatability (COR) were calculated for the semi-automated technique.
RESULTS: There were significant differences between white light and infrared illumination for PAH (p < 0.0001), blink rate (p = 0.04), closing speed (p = 0.009), opening speed (p < 0.0001) and blink duration (p = 0.0003). The mean differences (95% limits of agreement) between the two techniques were 0.6 mm s-1 (-15.9 to 17.0) closing speed, 1.5 mm s-1 (-6.8 to 9.8) opening speed, 2.4 ms (-6.8 to 11.5) closed phase duration and 5.0 ms (-19.4 to 29.3) total blink duration. COR values were 10.1 mm s-1 closing speed, 3.7 mm s-1 opening speed, 6.7 ms closed phase duration and 11.2 ms total blink duration.
CONCLUSIONS: This study has shown that spontaneous blinking can be characterised using a non-invasive imaging system. The semi-automated analysis provides a rapid characterisation of blink dynamics, allowing its application in large-scale trials in a number of clinical areas.
© 2020 The Authors Ophthalmic & Physiological Optics © 2020 The College of Optometrists.

Entities:  

Keywords:  blink speed; eyelids; image analysis; infrared imaging; non-invasive; spontaneous blinking

Mesh:

Year:  2020        PMID: 32452570     DOI: 10.1111/opo.12694

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  2 in total

1.  Impact of Incomplete Blinking Analyzed Using a Deep Learning Model With the Keratograph 5M in Dry Eye Disease.

Authors:  Qinxiang Zheng; Lei Wang; Han Wen; Yueping Ren; Shenghai Huang; Furong Bai; Na Li; Jennifer P Craig; Louis Tong; Wei Chen
Journal:  Transl Vis Sci Technol       Date:  2022-03-02       Impact factor: 3.283

2.  Evaluation of the Lubricating Effect of Hyaluronic Acid on Contact Lenses Using a Pendulum-Type Friction Tester Under Mimicking Physiological Conditions.

Authors:  Hiroko Iwashita; Kiyoshi Mabuchi; Takashi Itokawa; Yukinobu Okajima; Takashi Suzuki; Yuichi Hori
Journal:  Eye Contact Lens       Date:  2022-02-01       Impact factor: 2.018

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.