A simple pH-responsive magnetic solid-phase extraction method was developed using graphene oxide-coated nanoscale zerovalent iron nanoparticles as an efficient adsorbent prior to high-performance liquid chromatography-tandem mass spectrometry for determination of ultra-trace quinolones in milk samples. Various parameters affecting maghemite synthesis and separation such as pH of sample solution, amount of magnetic adsorbent, eluent type, and volume were optimized. The limits of detection are from 3.1 to 13.3 ng/L. The intra- and interprecision values are in the range of 2.9-6.9% and 7.6-15.1%, respectively. Recoveries are from 82.4 to 103.9%. Therefore, this simple and sensitive method is suitable for detecting ultra-trace quinolone residues in milk.Entities:
Keywords: high-performance liquid chromatography; magnetic graphene oxide; magnetic solid phase extraction; mass spectrometry; quinolones
Mesh:
Substances:
Year: 2020 PMID: 32449830 DOI: 10.1002/jssc.202000108