| Literature DB >> 3244972 |
F Y Ottensmeyer1, B W Frankland.
Abstract
Seven different one-, two-, or three-parameter analytic expressions were tested for their applicability to electron energy-loss spectral processing for mapping of atomic distributions in images of magnesium oxide crystals. Two-point two-parameter fits all provided indistinguishable results. Fine structure in the spectrum produced major quantitative inconsistencies for any given expression. This effect was exacerbated with the use of three-parameter expressions. Mass-thickness effects on the oxygen map of Mg0 were inconsequential up to a crystal thickness of 30 nm, but became dominant and unacceptable at a 50% increase in thickness above this. This observation can be explained by a specific single inelastic scatter coupled with any number of elastic scattering events.Entities:
Mesh:
Substances:
Year: 1988 PMID: 3244972
Source DB: PubMed Journal: Scanning Microsc Suppl ISSN: 0892-953X