Literature DB >> 32443746

Knee Wear Assessment: 3D Scanners Used as a Consolidated Procedure.

Saverio Affatato1, Maria Cristina Valigi2, Silvia Logozzo2,3.   

Abstract

It is well known that wear occurring in polyethylene menisci is a significant clinical problem. At this regard, wear tests on biomaterials medical devices are performed in order to assess their pre-clinical performance in terms of wear, durability, resistance to fatigue, etc. The objective of this study was to assess the wear of mobile total knee polyethylene inserts after an in vitro wear test. In particular, the wear behavior of mobile bearing polyethylene knee configurations was investigated using a knee joint wear simulator. After the completion of the wear test, the polyethylene mobile menisci were analyzed through a consolidated procedure by using 3D optical scanners, in order to evaluate the 3D wear distribution on the prosthesis surface, wear depths, wear rates, amount of material loss and contact areas. The results in terms of wear rates and wear volumes were compared with results of gravimetric tests, finding equivalent achievements.

Entities:  

Keywords:  3D optical wear measurements; 3D scanner; biotribology; mobile menisci; wear maps

Year:  2020        PMID: 32443746     DOI: 10.3390/ma13102349

Source DB:  PubMed          Journal:  Materials (Basel)        ISSN: 1996-1944            Impact factor:   3.623


  5 in total

1.  A methodology to evaluate contact areas and indentations of human fingertips based on 3D techniques for haptic purposes.

Authors:  Silvia Logozzo; Maria Cristina Valigi; Monica Malvezzi
Journal:  MethodsX       Date:  2022-07-08

2.  Upper Limb Design of an Anthropometric Crash Test Dummy for Low Impact Rates.

Authors:  Marek Jaśkiewicz; Damian Frej; Dariusz Tarnapowicz; Milos Poliak
Journal:  Polymers (Basel)       Date:  2020-11-10       Impact factor: 4.329

3.  Development of a Three-Dimensional Optical Verification Technology without Environmental Pollution for Metal Components with Different Surface Properties.

Authors:  Chil-Chyuan Kuo; Zong-Yan He; Chil-Xian Lee
Journal:  Materials (Basel)       Date:  2022-09-04       Impact factor: 3.748

4.  An Environmentally-Friendly Three-Dimensional Computer-Aided Verification Technique for Plastic Parts.

Authors:  Chil-Chyuan Kuo; Zong-Yan He; Chil-Xian Lee
Journal:  Polymers (Basel)       Date:  2022-07-24       Impact factor: 4.967

5.  Wear Morphology on the Surfaces of CoCrMo Unicompartmental Knee Joint Endoprostheses as Elements of Metal-Metal Friction Nodes.

Authors:  Arkadiusz Szarek; Grzegorz Stradomski; Justyna Łukomska-Szarek; Dariusz Rydz; Wojciech Wolański; Kamil Joszko
Journal:  Materials (Basel)       Date:  2020-06-12       Impact factor: 3.623

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.