Literature DB >> 3244272

An improved analytical method, based on HPLC with electrochemical detection, for monitoring exposure to 3-chloro-4-fluoroaniline.

C V Eadsforth1, P C Coveney, W H Sjoe.   

Abstract

An HPLC method for monitoring exposure of workers to 3-chloro-4-fluoroaniline (CFA) is described. It is based on the detection of a major urinary metabolite, 2-amino-4-chloro-5-fluorophenyl sulphate, and is superior to the previously adopted GC method. The limit of detection for the metabolite, 2-amino-4-chloro-5-fluorophenyl sulphate, is less than or equal to 0.01 mg/L (as CFA equivalent), with a coefficient of variation obtained over the range 1-15 mg/L of 4%. The HPLC method avoids the need for derivatization (cf. GC) and is consequently a much quicker and cheaper monitoring method. Urine samples from plant workers may be stored at 4 degrees C for a period of three months without loss of the metabolite.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3244272     DOI: 10.1093/jat/12.6.330

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  1 in total

1.  Biological monitoring of exposure to 3-chloro-4-fluoroaniline by determination of a urinary metabolite and a hemoglobin adduct.

Authors:  P J Boogaard; G D Beulink; N J van Sittert