BACKGROUND: Biventricular (BIV) ICD implantations are traditionally performed using contrast and fluoroscopic guidance. Contrast use in patient with advanced renal disease can cause deterioration of renal function and even lead to dialysis.
OBJECTIVE: To evaluate the feasibility of utilizing 3 D mapping technique in reducing or eliminating contrast use in patient with advanced renal disease. METHODS AND
RESULTS: The study consisted of 30 consecutive adult patients, in which BIV implantation was accomplished in advanced renal disease (stage III and IV GFR 15 to 59) by electroanatomical 3D mapping (EAM).Acute procedural success was 96% and only one patient LV lead implantation was unsuccessful due to unsuitable anatomy.47 % of patients had BIV ICD implantation with zero contrast. Average contrast exposure for the group was 4.3 ml only. Average ratio of contrast use to GFR (glomerular filtration rate) was only 0.1. Improved mean GFR was observed from 42 to 50 post procedure (P value<0.01), and continued to improve to 48 at 3 and 6 month (P value<0.01) and improvement decreased to 45 and 44 beyond 6 month and 1 year (P value NS). There was no single case of contrast induced acute renal insufficiency (CI-ARI) due to minimal use of contrast.69 % of the patients experienced an improvement in their functional class. A decrease in QRS duration was seen from 159 to 136 milliseconds (86% of patients had improved QRS duration); P value = <0.001. The average pre procedure ejection fraction (EF) for the group was 23%. The average EF post procedure for the group was 35%; P values = <0.001 (72% of patient had EF improvement).93% of patient had either EF and/or GFR improvement suggesting substantial clinical benefit from the procedure.There was no minor or major complications.
CONCLUSIONS: Implantation of BiV ICD using EAM with near zero contrast is feasible, safe and effective in patients with moderate to severe renal insufficiency. There is an added renal protection and benefit from procedure in this group of patients.

Entities:  

Keywords:  Advanced renal disease; BiV ICD; Near Zero Contrast; Three dimensional Electro-anatomical Mapping.

Year:  2019        PMID: 32435340      PMCID: PMC7237082          DOI: 10.4022/jafib.2156

Source DB:  PubMed          Journal:  J Atr Fibrillation        ISSN: 1941-6911


  11 in total

1.  Epidemiology and prognostic implications of contrast-induced nephropathy.

Authors:  Peter A McCullough; Andy Adam; Christoph R Becker; Charles Davidson; Norbert Lameire; Fulvio Stacul; James Tumlin
Journal:  Am J Cardiol       Date:  2006-02-10       Impact factor: 2.778

2.  2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA).

Authors:  Michele Brignole; Angelo Auricchio; Gonzalo Baron-Esquivias; Pierre Bordachar; Giuseppe Boriani; Ole-A Breithardt; John Cleland; Jean-Claude Deharo; Victoria Delgado; Perry M Elliott; Bulent Gorenek; Carsten W Israel; Christophe Leclercq; Cecilia Linde; Lluís Mont; Luigi Padeletti; Richard Sutton; Panos E Vardas; Jose Luis Zamorano; Stephan Achenbach; Helmut Baumgartner; Jeroen J Bax; Héctor Bueno; Veronica Dean; Christi Deaton; Cetin Erol; Robert Fagard; Roberto Ferrari; David Hasdai; Arno W Hoes; Paulus Kirchhof; Juhani Knuuti; Philippe Kolh; Patrizio Lancellotti; Ales Linhart; Petros Nihoyannopoulos; Massimo F Piepoli; Piotr Ponikowski; Per Anton Sirnes; Juan Luis Tamargo; Michal Tendera; Adam Torbicki; William Wijns; Stephan Windecker; Paulus Kirchhof; Carina Blomstrom-Lundqvist; Luigi P Badano; Farid Aliyev; Dietmar Bänsch; Helmut Baumgartner; Walid Bsata; Peter Buser; Philippe Charron; Jean-Claude Daubert; Dan Dobreanu; Svein Faerestrand; David Hasdai; Arno W Hoes; Jean-Yves Le Heuzey; Hercules Mavrakis; Theresa McDonagh; Jose Luis Merino; Mostapha M Nawar; Jens Cosedis Nielsen; Burkert Pieske; Lidija Poposka; Frank Ruschitzka; Michal Tendera; Isabelle C Van Gelder; Carol M Wilson
Journal:  Eur Heart J       Date:  2013-06-24       Impact factor: 29.983

3.  A novel method for nonfluoroscopic catheter-based electroanatomical mapping of the heart. In vitro and in vivo accuracy results.

Authors:  L Gepstein; G Hayam; S A Ben-Haim
Journal:  Circulation       Date:  1997-03-18       Impact factor: 29.690

4.  The importance of contrast volume/glomerular filtration rate ratio in contrast-induced nephropathy patients after transcatheter aortic valve implantation.

Authors:  Ilker Gul; Mustafa Zungur; Ahmet Tastan; Faik Fevzi Okur; Ertan Damar; Samet Uyar; Veysel Sahin; Talat Tavli
Journal:  Cardiorenal Med       Date:  2014-12-20       Impact factor: 2.041

5.  Near zero fluoroscopic implantation of BIV ICD using electro-anatomical mapping.

Authors:  Adel Mina; Nicholas Warnecke
Journal:  Pacing Clin Electrophysiol       Date:  2013-07-31       Impact factor: 1.976

6.  Impact of radiocontrast use during left ventricular pacemaker lead implantation for cardiac resynchronization therapy.

Authors:  Gregory A Tester; Amit Noheria; Heather L Carrico; Jennifer A Mears; Yong-Mei Cha; Brian D Powell; Paul A Friedman; Robert F Rea; David L Hayes; Samuel J Asirvatham
Journal:  Europace       Date:  2011-10-23       Impact factor: 5.214

7.  Contrast nephropathy post cardiac resynchronization therapy: an under-recognized complication with important morbidity.

Authors:  Peter J Cowburn; Harshna Patel; Rebecca R Pipes; John D Parker
Journal:  Eur J Heart Fail       Date:  2005-08       Impact factor: 15.534

8.  Association Between Contrast Media Volume-Glomerular Filtration Rate Ratio and Contrast-Induced Acute Kidney Injury After Primary Percutaneous Coronary Intervention.

Authors:  Omer Celik; Derya Ozturk; Fatih Akin; Burak Ayca; Ahmet Arif Yalcın; Mehmet Erturk; Ismail Bıyık; Ahmet Ayaz; Ibrahim Faruk Akturk; Asım Enhos; Serkan Aslan
Journal:  Angiology       Date:  2014-07-08       Impact factor: 3.619

9.  Near-zero fluoroscopy implantation of dual-chamber pacemaker in pregnancy using electroanatomic mapping.

Authors:  Jason Payne; Monica Lo; Hakan Paydak; Waddah Maskoun
Journal:  HeartRhythm Case Rep       Date:  2017-01-27

10.  Contrast-induced acute kidney injury in patients undergoing cardiac resynchronization therapy-incidence and prognostic importance. Sub-analysis of data from randomized TRUST CRT trial.

Authors:  Jacek Kowalczyk; Radoslaw Lenarczyk; Oskar Kowalski; Tomasz Podolecki; Pawel Francuz; Patrycja Pruszkowska-Skrzep; Mariola Szulik; Michal Mazurek; Ewa Jedrzejczyk-Patej; Beata Sredniawa; Zbigniew Kalarus
Journal:  J Interv Card Electrophysiol       Date:  2014-03-14       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.