Jason J LeBlanc1, Charles Heinstein2, Jimmy MacDonald2, Janice Pettipas3, Todd F Hatchette1, Glenn Patriquin4.
Abstract
Given the global shortage of nasopharyngeal (NP) swabs typically used for respiratory virus detection, alternative collection methods were evaluated during the COVID-19 pandemic. This study showed that a combined oropharyngeal/nares swab is a suitable alternative to NP swabs for the detection of SARS-CoV-2, with sensitivities of 91.7% and 94.4%, respectively.Keywords: COVID-19; Nares; Oropharyngeal; PCR; SARS-CoV-2; SWAB
Year: 2020 PMID: 32425660 PMCID: PMC7228872 DOI: 10.1016/j.jcv.2020.104442