Literature DB >> 32425020

Hard and soft tissue changes in the rehabilitation of the anterior maxilla with triangular shape neck implants: a retrospective clinical study with a one-year follow up.

F D'Avenia1, M Del Fabbro2,3, L Karanxha2, T Weinstein4, S Corbella2,3, D Fumagalli2, L Francetti2,3, S Taschieri2,3.   

Abstract

Aim of this retrospective study was to evaluate the one-year clinical and radiographic outcomes of implants with a triangular shaped neck inserted immediately after tooth extraction in esthetic zones. Patients in which immediate postextraction implants were placed and restored in the anterior maxilla, who underwent a Cone Beam Computed Tomograpy (CBCT) at baseline and after 12-16 months were included. The socket was preserved using deproteinized bovine bone to fill the buccal gap, and a resorbable collagen membrane. One-year implant survival and prosthesis success were evaluated. Hard and soft tissue stability was assessed by measuring various parameters on CBCT images. Clinical evaluation was also performed and Pink Esthetic Score (PES) assessed. Data from baseline and one-year follow-up were statistically compared using paired tests and a significance threshold of p=0.05. Twenty patients (13 males, 7 females, mean age 50.42±11.35 years) were included. Each contributed with one implant. No implant was lost. A significant improvement in PES was detected. Excellent hard and soft tissue preservation was observed after one year of function. Immediate placement of implants with a triangular shaped neck after tooth extraction, can be a suitable solution even for areas with a high aesthetic demand, such as the anterior maxilla. Copyright 2020 Biolife Sas. www.biolifesas.org.

Entities:  

Keywords:  CBCT; alveolar socket preservation; anterior maxilla; dental implants; hard tissue changes; immediate implants; soft tissue changes

Mesh:

Substances:

Year:  2019        PMID: 32425020

Source DB:  PubMed          Journal:  J Biol Regul Homeost Agents        ISSN: 0393-974X            Impact factor:   1.711


  2 in total

1.  Clinical and Radiographic Evaluation of a Novel Triangular Implant Neck Design: A Case Series.

Authors:  James Rudolph Collins; Brendha P Ogando; Houlin Hong; Wei Hou; Georgios E Romanos
Journal:  Dent J (Basel)       Date:  2022-06-16

2.  Covariates Relating to Implant Failure and Marginal Bone Loss of a Novel Triangular Neck-Implant Placed by Post-Graduate Students: A 1-Year Prospective Cohort Study.

Authors:  Maria Giralt-Hernando; Gian Maria Ragucci; Oriol Cantó-Naves; Adaia Valls-Ontañón; Federico Hernández-Alfaro
Journal:  Materials (Basel)       Date:  2022-03-08       Impact factor: 3.623

  2 in total