Literature DB >> 32423551

Effect of luting materials, presence of tooth preparation, and functional loading on stress distribution on ceramic laminate veneers: A finite element analysis.

Gabriel Felipe de Bragança1, Júlia Dantas Mazão2, Antheunis Versluis3, Carlos José Soares4.   

Abstract

STATEMENT OF PROBLEM: How the polymerization shrinkage, loading, and mechanical properties of luting materials affect the shrinkage and functional stresses in ceramic laminate veneers (CLVs) with and without tooth preparation is unclear.
PURPOSE: The purpose of this finite element analysis (FEA) study was to evaluate the effect of the polymerization shrinkage, functional loading, and mechanical properties of different luting materials on the stresses in ultrathin 0.3-mm CLVs with and without tooth preparation.
MATERIAL AND METHODS: Three resin cements, RelyX Veneer (RV), Allcem Veneer APS (AV), Variolink Esthetic LC (VE), and 1 flowable composite resin, Tetric N-Flow (TF), were tested for post-gel shrinkage (Shr), Knoop hardness (KHN), elastic modulus (E), compressive strength (CS), and diametral tensile strength (DTS). IPS e.max CAD disks of 0.3-mm thickness were made for simulating the effects of light attenuation. Eight 2-dimensional finite element models (Marc-Mentat) of a maxillary central incisor were generated to evaluate the polymerization shrinkage stress of different materials for luting 0.3-mm CLVs with or without tooth preparation and the stress during functional loading by using a modified von Mises criterion (mvm). Collected data from Shr, KHN, and E were submitted to 2-way ANOVA and the Tukey HSD test (α=.05).
RESULTS: Light attenuation by the 0.3-mm ceramic disk did not significantly affect the E values, but Shr was significantly lower in VE (26%) and TF (35%). TF had lower volumetric Shr (%) when interposing a ceramic disk (0.31%). Both tested tooth preparation options showed similar stress distributions from polymerization shrinkage or functional loading, with higher stress concentration on the incisal edge and also on the cervical surface. The model featuring tooth preparation and RV resin cement had the highest and VE the lowest stress levels.
CONCLUSIONS: The flowable composite resin had similar mechanical properties as the resin cements. The stress distribution from shrinkage and functional loading was similar for both techniques with or without tooth preparation.
Copyright © 2020 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2020        PMID: 32423551     DOI: 10.1016/j.prosdent.2020.02.005

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  1 in total

1.  Resistance fracture of minimally prepared endocrowns made by three types of restorative materials: a 3D finite element analysis.

Authors:  Qingzhen Meng; Yuejiao Zhang; Danlu Chi; Qimei Gong; Zhongchun Tong
Journal:  J Mater Sci Mater Med       Date:  2021-10-30       Impact factor: 3.896

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.