A deep neural network for fast and accurate scatter estimation in quantitative SPECT/CT under challenging scatter conditions.

Haowei Xiang1, Hongki Lim1, Jeffrey A Fessler1, Yuni K Dewaraja2.   

Abstract

PURPOSE: A major challenge for accurate quantitative SPECT imaging of some radionuclides is the inadequacy of simple energy window-based scatter estimation methods, widely available on clinic systems. A deep learning approach for SPECT/CT scatter estimation is investigated as an alternative to computationally expensive Monte Carlo (MC) methods for challenging SPECT radionuclides, such as 90Y.
METHODS: A deep convolutional neural network (DCNN) was trained to separately estimate each scatter projection from the measured 90Y bremsstrahlung SPECT emission projection and CT attenuation projection that form the network inputs. The 13-layer deep architecture consisted of separate paths for the emission and attenuation projection that are concatenated before the final convolution steps. The training label consisted of MC-generated "true" scatter projections in phantoms (MC is needed only for training) with the mean square difference relative to the model output serving as the loss function. The test data set included a simulated sphere phantom with a lung insert, measurements of a liver phantom, and patients after 90Y radioembolization. OS-EM SPECT reconstruction without scatter correction (NO-SC), with the true scatter (TRUE-SC) (available for simulated data only), with the DCNN estimated scatter (DCNN-SC), and with a previously developed MC scatter model (MC-SC) were compared, including with 90Y PET when available.
RESULTS: The contrast recovery (CR) vs. noise and lung insert residual error vs. noise curves for images reconstructed with DCNN-SC and MC-SC estimates were similar. At the same noise level of 10% (across multiple realizations), the average sphere CR was 24%, 52%, 55%, and 67% for NO-SC, MC-SC, DCNN-SC, and TRUE-SC, respectively. For the liver phantom, the average CR for liver inserts were 32%, 73%, and 65% for NO-SC, MC-SC, and DCNN-SC, respectively while the corresponding values for average contrast-to-noise ratio (visibility index) in low-concentration extra-hepatic inserts were 2, 19, and 61, respectively. In patients, there was high concordance between lesion-to-liver uptake ratios for SPECT reconstruction with DCNN-SC (median 4.8, range 0.02-13.8) compared with MC-SC (median 4.0, range 0.13-12.1; CCC = 0.98) and with 90Y PET (median 4.9, range 0.02-11.2; CCC = 0.96) while the concordance with NO-SC was poor (median 2.8, range 0.3-7.2; CCC = 0.59). The trained DCNN took ~ 40 s (using a single i5 processor on a desktop computer) to generate the scatter estimates for all 128 views in a patient scan, compared to ~ 80 min for the MC scatter model using 12 processors.
CONCLUSIONS: For diverse 90Y test data that included patient studies, we demonstrated comparable performance between images reconstructed with deep learning and MC-based scatter estimates using metrics relevant for dosimetry and for safety. This approach that can be generalized to other radionuclides by changing the training data is well suited for real-time clinical use because of the high speed, orders of magnitude faster than MC, while maintaining high accuracy.

Entities:  

Keywords:  90Y; Convolutional neural network (CNN); Deep learning; Monte Carlo methods; Radioembolization; SPECT/CT; Scatter correction

Mesh:

Year:  2020        PMID: 32415551      PMCID: PMC7666660          DOI: 10.1007/s00259-020-04840-9

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  16 in total

1.  Joint correction of attenuation and scatter in image space using deep convolutional neural networks for dedicated brain 18F-FDG PET.

Authors:  Jaewon Yang; Dookun Park; Grant T Gullberg; Youngho Seo
Journal:  Phys Med Biol       Date:  2019-04-04       Impact factor: 3.609

2.  PET image denoising using unsupervised deep learning.

Authors:  Jianan Cui; Kuang Gong; Ning Guo; Chenxi Wu; Xiaxia Meng; Kyungsang Kim; Kun Zheng; Zhifang Wu; Liping Fu; Baixuan Xu; Zhaohui Zhu; Jiahe Tian; Huafeng Liu; Quanzheng Li
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-08-29       Impact factor: 9.236

3.  Quantitative accuracy of clinical 99mTc SPECT/CT using ordered-subset expectation maximization with 3-dimensional resolution recovery, attenuation, and scatter correction.

Authors:  Johannes Zeintl; Alexander Hans Vija; Amos Yahil; Joachim Hornegger; Torsten Kuwert
Journal:  J Nucl Med       Date:  2010-05-19       Impact factor: 10.057

4.  Improved quantitative 90 Y bremsstrahlung SPECT/CT reconstruction with Monte Carlo scatter modeling.

Authors:  Yuni K Dewaraja; Se Young Chun; Ravi N Srinivasa; Ravi K Kaza; Kyle C Cuneo; Bill S Majdalany; Paula M Novelli; Michael Ljungberg; Jeffrey A Fessler
Journal:  Med Phys       Date:  2017-10-28       Impact factor: 4.071

5.  Quantitative Monte Carlo-based 90Y SPECT reconstruction.

Authors:  Mattijs Elschot; Marnix G E H Lam; Maurice A A J van den Bosch; Max A Viergever; Hugo W A M de Jong
Journal:  J Nucl Med       Date:  2013-08-01       Impact factor: 10.057

6.  DeepPET: A deep encoder-decoder network for directly solving the PET image reconstruction inverse problem.

Authors:  Ida Häggström; C Ross Schmidtlein; Gabriele Campanella; Thomas J Fuchs
Journal:  Med Image Anal       Date:  2019-03-30       Impact factor: 8.545

7.  Image Reconstruction: From Sparsity to Data-adaptive Methods and Machine Learning.

Authors:  Saiprasad Ravishankar; Jong Chul Ye; Jeffrey A Fessler
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2019-09-19       Impact factor: 10.961

8.  Deep learning-based attenuation map generation for myocardial perfusion SPECT.

Authors:  Luyao Shi; John A Onofrey; Hui Liu; Yi-Hwa Liu; Chi Liu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2020-03-26       Impact factor: 9.236

9.  Denoising of Scintillation Camera Images Using a Deep Convolutional Neural Network: A Monte Carlo Simulation Approach.

Authors:  David Minarik; Olof Enqvist; Elin Trägårdh
Journal:  J Nucl Med       Date:  2019-07-19       Impact factor: 11.082

10.  Accelerated SPECT image reconstruction with FBP and an image enhancement convolutional neural network.

Authors:  Martijn M A Dietze; Woutjan Branderhorst; Britt Kunnen; Max A Viergever; Hugo W A M de Jong
Journal:  EJNMMI Phys       Date:  2019-07-29
View more
  6 in total

Review 1.  Applications of artificial intelligence in nuclear medicine image generation.

Authors:  Zhibiao Cheng; Junhai Wen; Gang Huang; Jianhua Yan
Journal:  Quant Imaging Med Surg       Date:  2021-06

Review 2.  Application of artificial intelligence in nuclear medicine and molecular imaging: a review of current status and future perspectives for clinical translation.

Authors:  Dimitris Visvikis; Philippe Lambin; Kim Beuschau Mauridsen; Roland Hustinx; Michael Lassmann; Christoph Rischpler; Kuangyu Shi; Jan Pruim
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-07-09       Impact factor: 9.236

Review 3.  Artificial intelligence in single photon emission computed tomography (SPECT) imaging: a narrative review.

Authors:  Wenyi Shao; Steven P Rowe; Yong Du
Journal:  Ann Transl Med       Date:  2021-05

Review 4.  Advanced imaging for risk stratification for ventricular arrhythmias and sudden cardiac death.

Authors:  Eric Xie; Eric Sung; Elie Saad; Natalia Trayanova; Katherine C Wu; Jonathan Chrispin
Journal:  Front Cardiovasc Med       Date:  2022-08-22

5.  Challenges and advances in optical 3D mesoscale imaging.

Authors:  Sebastian Munck; Christopher Cawthorne; Abril Escamilla-Ayala; Axelle Kerstens; Sergio Gabarre; Katrina Wesencraft; Eliana Battistella; Rebecca Craig; Emmanuel G Reynaud; Jim Swoger; Gail McConnell
Journal:  J Microsc       Date:  2022-05-05       Impact factor: 1.952

6.  Nuclear Segmentation in Histopathological Images Using Two-Stage Stacked U-Nets With Attention Mechanism.

Authors:  Yan Kong; Georgi Z Genchev; Xiaolei Wang; Hongyu Zhao; Hui Lu
Journal:  Front Bioeng Biotechnol       Date:  2020-10-26
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.