TriB-RT: Simultaneous optimization of photon, electron and proton beams.

R Kueng1, S Mueller1, H A Loebner1, D Frei1, W Volken1, D M Aebersold1, M F M Stampanoni2, M K Fix1, P Manser1.   

Abstract

PURPOSE: To develop a novel treatment planning process (TPP) with simultaneous optimization of modulated photon, electron and proton beams for improved treatment plan quality in radiotherapy.
METHODS: A framework for fluence map optimization of Monte Carlo (MC) calculated beamlet dose distributions is developed to generate treatment plans consisting of photon, electron and spot scanning proton fields. Initially, in-house intensity modulated proton therapy (IMPT) plans are compared to proton plans created by a commercial treatment planning system (TPS). A triple beam radiotherapy (TriB-RT) plan is generated for an exemplary academic case and the dose contributions of the three particle types are investigated. To investigate the dosimetric potential, a TriB-RT plan is compared to an in-house IMPT plan for two clinically motivated cases. Benefits of TriB-RT for a fixed proton beam line with a single proton field are investigated.
RESULTS: In-house optimized IMPT are of at least equal or better quality than TPS-generated proton plans, and MC-based optimization shows dosimetric advantages for inhomogeneous situations. Concerning TriB-RT, for the academic case, the resulting plan shows substantial contribution of all particle types. For the clinically motivated case, improved sparing of organs at risk close to the target volume is achieved compared to IMPT (e.g. myelon and brainstem [Formula: see text] -37%) at cost of an increased low dose bath (healthy tissue V 10% +22%). In the scenario of a fixed proton beam line, TriB-RT plans are able to compensate the loss in degrees of freedom to substantially improve plan quality compared to a single field proton plan.
CONCLUSION: A novel TPP which simultaneously optimizes photon, electron and proton beams was successfully developed. TriB-RT shows the potential for improved treatment plan quality and is especially promising for cost-effective single-room proton solutions with a fixed beamline in combination with a conventional linac delivering photon and electron fields.

Entities:  

Mesh:

Year:  2021        PMID: 32413883     DOI: 10.1088/1361-6560/ab936f

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

1.  A treatment planning study of combined carbon ion-beam plus photon intensity-modulated radiotherapy.

Authors:  Christopher Schuppert; Angela Paul; Simeon Nill; Andrea Schwahofer; Jürgen Debus; Florian Sterzing
Journal:  Phys Imaging Radiat Oncol       Date:  2020-07-10

2.  Combined proton-photon therapy for non-small cell lung cancer.

Authors:  Florian Amstutz; Silvia Fabiano; Louise Marc; Damien Charles Weber; Antony John Lomax; Jan Unkelbach; Ye Zhang
Journal:  Med Phys       Date:  2022-05-25       Impact factor: 4.506