Preoperative localization of seizure onset zones by magnetic source imaging, EEG-correlated functional MRI, and their combination.

Assaf Berger1,2, Noa Cohen3,2, Firas Fahoum4,2, Mordekhay Medvedovsky5,6, Aaron Meller3,2, Dana Ekstein5,6, Mony Benifla7,8, Orna Aizenstein9,2, Itzhak Fried1,2, Tomer Gazit3,2, Ido Strauss1,2.   

Abstract

OBJECTIVE: Preoperative localization of seizure onset zones (SOZs) is an evolving field in the treatment of refractory epilepsy. Both magnetic source imaging (MSI), and the more recent EEG-correlated functional MRI (EEG-fMRI), have shown applicability in assisting surgical planning. The purpose of this study was to evaluate the capability of each method and their combination in localizing the seizure onset lobe (SL).
METHODS: The study included 14 patients who underwent both MSI and EEG-fMRI before undergoing implantation of intracranial EEG (icEEG) as part of the presurgical planning of the resection of an epileptogenic zone (EZ) during the years 2012-2018. The estimated location of the SL by each method was compared with the location determined by icEEG. Identification rates of the SL were compared between the different methods.
RESULTS: MSI and EEG-fMRI showed similar identification rates of SL locations in relation to icEEG results (88% ± 31% and 73% ± 42%, respectively; p = 0.281). The additive use of the coverage lobes of both methods correctly identified 100% of the SL, significantly higher than EEG-fMRI alone (p = 0.039) and nonsignificantly higher than MSI (p = 0.180). False-identification rates of the additive coverage lobes were significantly higher than MSI (p = 0.026) and EEG-fMRI (p = 0.027). The intersecting lobes of both methods showed the lowest false identification rate (13% ± 6%, p = 0.01).
CONCLUSIONS: Both MSI and EEG-fMRI can assist in the presurgical evaluation of patients with refractory epilepsy. The additive use of both tests confers a high identification rate in finding the SL. This combination can help in focusing implantation of icEEG electrodes targeting the SOZ.

Entities:  

Keywords:  EEG-fMRI; MSI; icEEG; magnetic source imaging; refractory epilepsy; seizure onset zone

Mesh:

Year:  2020        PMID: 32413858     DOI: 10.3171/2020.3.JNS192794

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  2 in total

1.  Clinical Yield of Electromagnetic Source Imaging and Hemodynamic Responses in Epilepsy: Validation With Intracerebral Data.

Authors:  Chifaou Abdallah; Tanguy Hedrich; Andreas Koupparis; Jawata Afnan; Jeffrey Alan Hall; Jean Gotman; Francois Dubeau; Nicolas von Ellenrieder; Birgit Frauscher; Eliane Kobayashi; Christophe Grova
Journal:  Neurology       Date:  2022-04-26       Impact factor: 11.800

Review 2.  A systematic review of magnetic resonance imaging in patients with an implanted vagus nerve stimulation system.

Authors:  S Fetzer; M Dibué; A M Nagel; R Trollmann
Journal:  Neuroradiology       Date:  2021-04-12       Impact factor: 2.804

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.