Correction to: Monitoring quality of care for peripheral intravenous catheters; feasibility and reliability of the peripheral intravenous catheters mini questionnaire (PIVC-miniQ).

Lise Husby Høvik1,2,3, Kari Hanne Gjeilo4,5,6, Stian Lydersen7, Claire M Rickard8,9, Benedikte Røtvold10, Jan Kristian Damås11,12,13, Erik Solligård4,11,14, Lise Tuset Gustad4,11,15.   

Abstract

An amendment to this paper has been published and can be accessed via the original article.

Entities:  

Year:  2020        PMID: 32410679      PMCID: PMC7222580          DOI: 10.1186/s12913-020-05300-8

Source DB:  PubMed          Journal:  BMC Health Serv Res        ISSN: 1472-6963            Impact factor:   2.655


Correction to: BMC Health Serv (2019) Res 19: 636. https://doi.org/10.1186/s12913-019-4497-z Following publication of the original article [1], the authors identified an error in Table 3. In Table 3, column 8, the heading is “Positive agreement”. It should be “Absolute agreement” and the last column was wrong both in heading and in contents. The changes do not have impact on the interpretation of our data, discussion and conclusions.
Table 3

Agreement and reliability results for the 16 items of the Peripheral Intravenous Catheters mini questionnaire (PIVC miniQ)

Item on the PIVC miniQnegdisagreepositivesumNegative agreementPositive agreementAbsolute agreementScott’s pi
PIVC Pain and tenderness16815222050.9570.7460.9270.703
Redness > 1 cm from insertion site16726122050.9280.4800.8730.408
Swelling> 1 cm from insertion site1951002050.9750.0000.951−0.025
Warmth at insertion site199512050.9880.2860.9760.273
Purulence200412050.9900.3330.9810.323
Streak/red line along the vein199422050.9900.5000.9810.490
Induration, hardness of tissue197712050.9830.2220.9660.205
Palpable hard vein beyond tip1901322050.9670.2350.9370.202
Partial/complete dislodgement201222050.9950.6670.9900.662
Soiled with blood or fluids14621382050.9330.7840.8980.716
Loose or lifting dressing edges15623262050.9310.6930.8890.625
Fixed with tape only202302050.9930.0000.985−0.007
Blood in line13339332050.8720.6290.8100.501
Insertion date not documented on PIVC dressing85181022050.9040.9190.9120.823
Indication unknown16921152050.9420.5880.8980.531
PIVC insertion date in is chart is lacking13236372050.8800.6730.8240.553

PIVC Peripheral Intravenous Catheter

The correct table is given below. Agreement and reliability results for the 16 items of the Peripheral Intravenous Catheters mini questionnaire (PIVC miniQ) PIVC Peripheral Intravenous Catheter
  1 in total

1.  Monitoring quality of care for peripheral intravenous catheters; feasibility and reliability of the peripheral intravenous catheters mini questionnaire (PIVC-miniQ).

Authors:  Lise Husby Høvik; Kari Hanne Gjeilo; Stian Lydersen; Claire M Rickard; Benedikte Røtvold; Jan Kristian Damås; Erik Solligård; Lise Tuset Gustad
Journal:  BMC Health Serv Res       Date:  2019-09-05       Impact factor: 2.655

  1 in total
  1 in total

1.  Quality of care for peripheral intravenous catheters (PIVCs) in Nepal: a cross-sectional study on feasibility and inter-rater agreement of the Peripheral Intravenous Catheters-mini Questionnaire (PIVC-miniQ) in a tertiary care hospital.

Authors:  Sulekha Shrestha; Johannes Vieler; Nikolai Juliussen Haug; Jan Egil Afset; Lise Husby Høvik; Stian Lydersen; Lise Tuset Gustad
Journal:  BMJ Open       Date:  2021-07-16       Impact factor: 2.692

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.