Lifeng Wang 1 , Xingxing Jin 2 , Zhenguo Qiao 3 , Bin Xu 1 , Jiaqing Shen 4 . Show Affiliations »
Abstract
OBJECTIVES: This study investigated the radiation dose and value of prospective dualenergy computed tomography (DECT) in the diagnosis of gastric cancer. METHODS: Sixty patients scheduled for computed tomography (CT) for preoperative staging were divided into two groups. Thirty patients (Group A) underwent a single contrast-enhanced abdominal CT acquisition using a dual-source mode (100 kV/140 kV). Weighted average images of the two-kilovolt acquisitions and iodine maps were created. The remaining 30 patients underwent a standard CT scan (Group B). Two observers performed a blinded read of the images for gastric lesions, evaluating the image quality and recording effective dose. RESULTS: During the blinded read, observers found 90% (27/30) of the cancers in both groups. The mean imaging quality scores were 2.1±0.9 for Group A, and 2.3±1.1 for Group B. The effective mean doses were 6.59±0.59 mSv and 25.86±0.44 mSv for Groups A and B, respectively. Compared with the control group (B), the imaging quality in the low-dose group decreased a little, but the radiation dose substantially decreased by 74.6%. CONCLUSION: The new DECT technique is valuable for examining gastric cancer patients. The dualkV scan mode can substantially reduce radiation dose while preserving good diagnostic image quality. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.net.
OBJECTIVES: This study investigated the radiation dose and value of prospective dualenergy computed tomography (DECT) in the diagnosis of gastric cancer . METHODS: Sixty patients scheduled for computed tomography (CT) for preoperative staging were divided into two groups. Thirty patients (Group A) underwent a single contrast-enhanced abdominal CT acquisition using a dual-source mode (100 kV/140 kV). Weighted average images of the two-kilovolt acquisitions and iodine maps were created. The remaining 30 patients underwent a standard CT scan (Group B). Two observers performed a blinded read of the images for gastric lesions , evaluating the image quality and recording effective dose. RESULTS: During the blinded read, observers found 90% (27/30) of the cancers in both groups. The mean imaging quality scores were 2.1±0.9 for Group A, and 2.3±1.1 for Group B. The effective mean doses were 6.59±0.59 mSv and 25.86±0.44 mSv for Groups A and B, respectively. Compared with the control group (B), the imaging quality in the low-dose group decreased a little, but the radiation dose substantially decreased by 74.6%. CONCLUSION: The new DECT technique is valuable for examining gastric cancer patients . The dualkV scan mode can substantially reduce radiation dose while preserving good diagnostic image quality. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.net.
Entities: Chemical
Disease
Species
Keywords:
Computed tomography (CT); DECT; diagnosis; gastric cancer; patients; radiation dose.
Mesh: See more »
Substances: See more »
Year: 2020
PMID: 32410543 DOI: 10.2174/1573405614666181023114051
Source DB: PubMed Journal: Curr Med Imaging