Literature DB >> 32409039

The neural tissue around SU-8 implants: A quantitative in vivo biocompatibility study.

Gergely Márton1, Estilla Zsófia Tóth2, Lucia Wittner3, Richárd Fiáth4, Domonkos Pinke5, Gábor Orbán6, Domokos Meszéna7, Ildikó Pál8, Edit Lelle Győri9, Zsófia Bereczki10, Ágnes Kandrács11, Katharina T Hofer12, Anita Pongrácz13, István Ulbert14, Kinga Tóth15.   

Abstract

The use of SU-8 material in the production of neural sensors has grown recently. Despite its widespread application, a detailed systematic quantitative analysis concerning its biocompatibility in the central nervous system is lacking. In this immunohistochemical study, we quantified the neuronal preservation and the severity of astrogliosis around SU-8 devices implanted in the neocortex of rats, after a 2 months survival. We found that the density of neurons significantly decreased up to a distance of 20 μm from the implant, with an averaged density decrease to 24 ± 28% of the control. At 20 to 40 μm distance from the implant, the majority of the neurons was preserved (74 ± 39% of the control) and starting from 40 μm distance from the implant, the neuron density was control-like. The density of synaptic contacts - examined at the electron microscopic level - decreased in the close vicinity of the implant, but it recovered to the control level as close as 24 μm from the implant track. The intensity of the astroglial staining significantly increased compared to the control region, up to 560 μm and 480 μm distance from the track in the superficial and deep layers of the neocortex, respectively. Electron microscopic examination revealed that the thickness of the glial scar was around 5-10 μm thin, and the ratio of glial processes in the neuropil was not more than 16% up to a distance of 12 μm from the implant. Our data suggest that neuronal survival is affected only in a very small area around the implant. The glial scar surrounding the implant is thin, and the presence of glial elements is low in the neuropil, although the signs of astrogliosis could be observed up to about 500 μm from the track. Subsequently, the biocompatibility of the SU-8 material is high. Due to its low cost fabrication and more flexible nature, SU-8 based devices may offer a promising approach to experimental and clinical applications in the future.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biocompatibility; Flexible; Glial scar; Neural interface; SU-8 polymer; Ultrastructure

Mesh:

Substances:

Year:  2020        PMID: 32409039     DOI: 10.1016/j.msec.2020.110870

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  8 in total

Review 1.  Recent Progress in Materials Chemistry to Advance Flexible Bioelectronics in Medicine.

Authors:  Gaurav Balakrishnan; Jiwoo Song; Chenchen Mou; Christopher J Bettinger
Journal:  Adv Mater       Date:  2022-01-27       Impact factor: 30.849

2.  A Parylene Neural Probe Array for Multi-Region Deep Brain Recordings.

Authors:  Xuechun Wang; Ahuva Weltman Hirschberg; Huijing Xu; Zachary Slingsby-Smith; Aziliz Lecomte; Kee Scholten; Dong Song; Ellis Meng
Journal:  J Microelectromech Syst       Date:  2022-06-22       Impact factor: 2.829

Review 3.  Progress on Designing a Chemical Retinal Prosthesis.

Authors:  Jiajia Wu; Corey M Rountree; Sai-Siva Kare; Pradeep Kumar Ramkumar; John D Finan; John B Troy
Journal:  Front Cell Neurosci       Date:  2022-06-10       Impact factor: 6.147

4.  POEMS (POLYMERIC OPTO-ELECTRO-MECHANICAL SYSTEMS) FOR ADVANCED NEURAL INTERFACES.

Authors:  Komal Kampasi; Ian Ladner; Jenny Zhou; Alicia Calónico Soto; Jose Hernandez; Susant Patra; Razi-Ul Haque
Journal:  Mater Lett       Date:  2020-11-18       Impact factor: 3.423

Review 5.  The Future of Neuroscience: Flexible and Wireless Implantable Neural Electronics.

Authors:  Eve McGlynn; Vahid Nabaei; Elisa Ren; Gabriel Galeote-Checa; Rupam Das; Giulia Curia; Hadi Heidari
Journal:  Adv Sci (Weinh)       Date:  2021-03-09       Impact factor: 16.806

6.  All-Polymer Printed Low-Cost Regenerative Nerve Cuff Electrodes.

Authors:  Laura M Ferrari; Bruno Rodríguez-Meana; Alberto Bonisoli; Annarita Cutrone; Silvestro Micera; Xavier Navarro; Francesco Greco; Jaume Del Valle
Journal:  Front Bioeng Biotechnol       Date:  2021-02-10

Review 7.  A Review: Electrode and Packaging Materials for Neurophysiology Recording Implants.

Authors:  Weiyang Yang; Yan Gong; Wen Li
Journal:  Front Bioeng Biotechnol       Date:  2021-01-14

8.  Assessing the Feasibility of Developing in vivo Neuroprobes for Parallel Intracellular Recording and Stimulation: A Perspective.

Authors:  Micha E Spira; Hadas Erez; Aviv Sharon
Journal:  Front Neurosci       Date:  2022-01-25       Impact factor: 4.677

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.