Literature DB >> 3240655

Applied potential tomography: a new technique for monitoring pulmonary function.

N D Harris1, A J Suggett, D C Barber, B H Brown.   

Abstract

An electrical impedance tomographic imaging system has been developed which can monitor changes in the resistivity of the thorax at a rate of 5 frames per second. There is a high correlation (r greater than 0.95) between changes in resistivity of the lungs and the volume of air inspired. Calibration of the system allows continuous monitoring of the level of ventilation on exercise up to a minute volume of 45 l min-1. The volumetric accuracy of the system is generally within +/- 10% of spirometric measurements. Studies of the effect of changes in posture on the calibration of the system show changes of between +9.5% and -3.8% in normal male subjects. The performance of the system compares favourably with existing techniques for the noninvasive monitoring of ventilation.

Entities:  

Mesh:

Year:  1988        PMID: 3240655     DOI: 10.1088/0143-0815/9/4a/014

Source DB:  PubMed          Journal:  Clin Phys Physiol Meas        ISSN: 0143-0815


  6 in total

1.  Electrical impedance tomography's correlation to lung volume is not influenced by anthropometric parameters.

Authors:  François Marquis; Nicolas Coulombe; Roberta Costa; Hervé Gagnon; Robert Guardo; Yoanna Skrobik
Journal:  J Clin Monit Comput       Date:  2006-05-11       Impact factor: 2.502

2.  Model for the dielectric properties of human lung tissue against frequency and air content.

Authors:  P Nopp; N D Harris; T X Zhao; B H Brown
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

3.  A new six-electrode electrical impedance technique for probing deep organs in the human body.

Authors:  Shamor Kanti Roy; Mohammad Abu Sayem Karal; Muhammad Abdul Kadir; Khondkar Siddique-E Rabbani
Journal:  Eur Biophys J       Date:  2019-09-16       Impact factor: 1.733

4.  Electrical impedance tomography in monitoring experimental lung injury.

Authors:  I Frerichs; G Hahn; T Schröder; G Hellige
Journal:  Intensive Care Med       Date:  1998-08       Impact factor: 17.440

5.  Body fluid distribution in man in space and effect of lower body negative pressure treatment.

Authors:  F J Baisch
Journal:  Clin Investig       Date:  1993-09

6.  Variability in EIT Images of Lung Ventilation as a Function of Electrode Planes and Body Positions.

Authors:  Jie Zhang; Robert Patterson
Journal:  Open Biomed Eng J       Date:  2014-06-27
  6 in total