Literature DB >> 32403561

Electrothermal-MEMS-induced nonlinear distortion correction in photoacoustic laparoscopy.

Chang Lu, Kedi Xiong, Yuanzheng Ma, Wuyu Zhang, Zhongwen Cheng, Sihua Yang.   

Abstract

Micro-electro-mechanical systems (MEMS) scanner has significant advantages of miniature size, fast response and high stability, which is particularly applicable to photoacoustic laparoscopy (PAL). However, tilt angle-voltage curve of electrothermal MEMS shows a nonlinear character, which leads to inevitable nonlinear distortion in photoacoustic imaging. To overcome this problem, a nonlinear distortion correction was developed for the high-resolution forward-scanning electrothermal-MEMS-based PAL. The adaptive resampling method (ARM) was introduced to adaptively calibrate the projection of non-uniform scanning region to match the uniform scanning region. The correction performed low time complexity and high portability owing to the adaptive capacity of distortion decomposition in the reconstruction of physical models. Compared with the sample structure, phantom experiments demonstrated that the distortion was calibrated in all directions and the corrected image provided up to 96.82% high structural similarity in local subset. Furthermore, ARM was applied to imaging the abdominal cavity of rat and the vascular morphology was corrected in real-time display within a delay less than 2 seconds. All these results demonstrated that the nonlinear distortion correction possessed timely and effective correction in PAL, which suggested that it had the potential to employ to any other electrothermal-MEMS-based photoacoustic imaging systems for accurate and quantitative functional imaging.

Entities:  

Year:  2020        PMID: 32403561     DOI: 10.1364/OE.392493

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  6 in total

1.  Noninvasive photoacoustic computed tomography/ultrasound imaging to identify high-risk atherosclerotic plaques.

Authors:  Xuewei Liu; Rongkang Gao; Chiyun Chen; Xiaobo Li; Chen Yu; Yejia Chen; Hongbin Liang; Min Xiao; Lei Dai; Shifeng Qiu; Xiaoyu Xin; Liang Song; Jinbin Liu; Chengbo Liu; Jiancheng Xiu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-07-23       Impact factor: 10.057

2.  Endoscopic optical coherence tomography angiography using inverse SNR-amplitude decorrelation features and electrothermal micro-electro-mechanical system raster scan.

Authors:  Lin Yao; Huakun Li; Kaiyuan Liu; Ziyi Zhang; Peng Li
Journal:  Quant Imaging Med Surg       Date:  2022-06

3.  Miniature all-optical flexible forward-viewing photoacoustic endoscopy probe for surgical guidance.

Authors:  Rehman Ansari; Edward Z Zhang; Adrien E Desjardins; Paul C Beard
Journal:  Opt Lett       Date:  2020-11-15       Impact factor: 3.776

Review 4.  Progress of clinical translation of handheld and semi-handheld photoacoustic imaging.

Authors:  Qian Chen; Wei Qin; Weizhi Qi; Lei Xi
Journal:  Photoacoustics       Date:  2021-03-19

5.  Visualizing tumor angiogenesis and boundary with polygon-scanning multiscale photoacoustic microscopy.

Authors:  Zhiqiang Xu; Yinhao Pan; Ningbo Chen; Silue Zeng; Liangjian Liu; Rongkang Gao; Jianhui Zhang; Chihua Fang; Liang Song; Chengbo Liu
Journal:  Photoacoustics       Date:  2022-02-23

6.  Spatial weight matrix in dimensionality reduction reconstruction for micro-electromechanical system-based photoacoustic microscopy.

Authors:  Yuanzheng Ma; Chang Lu; Kedi Xiong; Wuyu Zhang; Sihua Yang
Journal:  Vis Comput Ind Biomed Art       Date:  2020-09-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.