Hsin-Chia Lin1, Ming-Tai Lin2, Chun-An Chen2, Jui-Yu Hsu3, Su-Man Lin4, Mei-Hwan Wu2, Jou-Kou Wang5. 1. Department of Cardiology, National Taiwan University Children's Hospital, Taipei, Taiwan; Department of Pediatrics, National Taiwan University Hospital Yunlin Branch, Douliu, Yunlin, Taiwan. 2. Department of Cardiology, National Taiwan University Children's Hospital, Taipei, Taiwan. 3. Department of Pediatrics, Taipei Tzu Chi Hospital, Taipei, Taiwan. 4. Department of Anesthesiology, Taipei Veterans General Hospital, Taipei, Taiwan. 5. Department of Cardiology, National Taiwan University Children's Hospital, Taipei, Taiwan. Electronic address: jkww@ntuh.gov.tw.
Abstract
BACKGROUND/ PURPOSE: Outlet-type VSD is frequently associated with aortic valve prolapse that surgery is frequently required. The literature regarding outcomes of transcatheter closure of outlet-type VSDs is scant. This study was conducted to know the safety and efficacy of transcatheter closure of outlet-type ventricular septal defects (VSDs) with Amplatzer Duct Occluder II (ADO II). METHODS: Medical records of patients underwent attempted transcatheter closure of outlet-type VSD with ADO II between October 2013 and August 2019 were retrospectively reviewed. RESULTS: Among 49 patients, transcatheter closure was successful in 45 (91.8%; 33 males and 12 females; mean [± standard deviation] age and body weight: 15.8 (±17.7) years and 36.6 (±23.3) kg, respectively). The median VSD diameter was 4.0 mm (range: 1.2-6.0 mm). Device closure failed in four because the sheath could not be advanced through a prograde or retrograde route in one patient, occluder embolization in the two patients, and failed right ventricular disc anchoring in one patient. After a mean follow-up of 22.7 months (range: 0.3-51.1 months), only nine (20.0%) patients had increased severity in aortic regurgitation (AR) on the echocardiography. Preprocedural AR decreased in severity or even disappeared in 11 (24.4%) patients. No heart block or device failure occurred during follow-up. A trivial-to-small residual shunt was detected in 19 patients (42.2%) in the most recent echocardiography. CONCLUSION: Transcatheter closure of outlet-type VSDs with ADO II is feasible. Although no significant aggravation of AR was observed in the short-to-mid-term follow-up, long-term follow-up is mandatory.
BACKGROUND/ PURPOSE: Outlet-type VSD is frequently associated with aortic valve prolapse that surgery is frequently required. The literature regarding outcomes of transcatheter closure of outlet-type VSDs is scant. This study was conducted to know the safety and efficacy of transcatheter closure of outlet-type ventricular septal defects (VSDs) with Amplatzer Duct Occluder II (ADO II). METHODS: Medical records of patients underwent attempted transcatheter closure of outlet-type VSD with ADO II between October 2013 and August 2019 were retrospectively reviewed. RESULTS: Among 49 patients, transcatheter closure was successful in 45 (91.8%; 33 males and 12 females; mean [± standard deviation] age and body weight: 15.8 (±17.7) years and 36.6 (±23.3) kg, respectively). The median VSD diameter was 4.0 mm (range: 1.2-6.0 mm). Device closure failed in four because the sheath could not be advanced through a prograde or retrograde route in one patient, occluder embolization in the two patients, and failed right ventricular disc anchoring in one patient. After a mean follow-up of 22.7 months (range: 0.3-51.1 months), only nine (20.0%) patients had increased severity in aortic regurgitation (AR) on the echocardiography. Preprocedural AR decreased in severity or even disappeared in 11 (24.4%) patients. No heart block or device failure occurred during follow-up. A trivial-to-small residual shunt was detected in 19 patients (42.2%) in the most recent echocardiography. CONCLUSION: Transcatheter closure of outlet-type VSDs with ADO II is feasible. Although no significant aggravation of AR was observed in the short-to-mid-term follow-up, long-term follow-up is mandatory.