| Literature DB >> 32400349 |
Gesa Gnegel1,2, Cathrin Hauk1, Richard Neci3,4, Georges Mutombo4, Fidelis Nyaah5, Dorothee Wistuba6, Christine Häfele-Abah2, Lutz Heide1.
Abstract
Reports that chloroquine and hydroxychloroquine may be effective against COVID-19 have received worldwide attention, increasing the risk of the introduction of falsified versions of these medicines. Five different types of falsified chloroquine tablets were discovered between March 31, 2020 and April 4, 2020, in Cameroon and the Democratic Republic of Congo by locally conducted thin layer chromatographic analysis. Subsequent investigation by liquid chromatography and mass spectrometry in Germany proved the absence of detectable amounts of chloroquine and the presence of undeclared active pharmaceutical ingredients, that is, paracetamol and metronidazole, in four of the samples. The fifth sample contained chloroquine, but only 22% of the declared amount. Such products represent a serious risk to patients. Their occurrence exemplifies that once medicines or vaccines against COVID-19 may be developed, falsified products will enter the market immediately, especially in low- and middle-income countries (LMICs). Timely preparations for the detection of such products are required, including the establishment of appropriate screening technologies in LMICs.Entities:
Mesh:
Substances:
Year: 2020 PMID: 32400349 PMCID: PMC7263564 DOI: 10.4269/ajtmh.20-0363
Source DB: PubMed Journal: Am J Trop Med Hyg ISSN: 0002-9637 Impact factor: 2.345
Figure 1.Falsified samples of chloroquine (CQ) tablets identified in Cameroon and the Democratic Republic Congo, and their thin layer chromatographic (TLC) analysis[11]; see Supplemental Information for details of the analytical procedure. Each TLC plate shows two spots of the respective sample in the middle and two spots of authentic CQ (corresponding to 100% and 80% of the declared amount of the sample) on the left and the right, respectively. Thin layer chromatography plates were photographed in Cameroon and the Democratic Republic Congo with locally available equipment; therefore, the angle of photography is not uniform. The active principles listed at the bottom were identified by high-performance liquid chromatography according to the U.S. Pharmacopeiea and by liquid chromatography–high-resolution mass spectrometry analysis (see text). The CQ amount in sample I was calculated as CQ phosphate; the identity of the counterion (phosphate or sulfate) was not determined. (Photos: packaging,© G. G., C. H., and L. H.; TLC analysis,© F. N. and G. M.)
Falsified samples of chloroquine tablets identified in Cameroon and the DR Congo
| Sample code ( | I | II | III | IV | V |
|---|---|---|---|---|---|
| Stated product name | Chloroquine phosphate tablets U.S.P | Chloroquine phosphate tablets U.S.P. | Cloroquine [ | Chloroquine phosphate tablets U.S.P. | Chloroquine phosphate tablets U.S.P |
| Stated strength | 100 mg | 100 mg | 250 mg | 100 mg | 250 mg |
| Stated manufacturer | Jiangsu Pharmaceutical Inc., China | Jiangsu Pharmaceutical Inc., China | Dawa Limited, Kenya | Jiangsu Pharmaceutical Inc., China | Jlangsu [ |
| Batch number, mfg date, exp date | 660, August 2018, August 2022 | 660, May 2017, May 2021 | 1605059, May 2019, April 2023 | 660, May 2019, April 2023 | 660, September 2018, September 2022 |
| Found in | Limbe, Cameroon | Douala, Cameroon | Bukavu, DR Congo | Douala, Cameroon | Douala, Cameroon |
| Type of facility found in | Private pharmacy | Private pharmacy | Informal vendor | Private pharmacy | Informal vendor |
| Date of discovery | April 3, 2020 | March 31, 2020 | April 4, 2020 | April 4, 2020 | March 31, 2020 |
| Labeling inconsistencies | |||||
| Spelling errors | − | − | |||
| Invalid NAFDAC registration number | − | ||||
| Same batch number for different products | − |
DR = Democratic Republic; NAFDAC = National Agency for Food and Drug Administration and Control, Nigeria. NAFDAC registration numbers were checked using the NAFDAC Registered Products Database available at www.nafdac.gov.ng/our-services/registered-products/.
Figure 2.High-performance liquid chromatography analysis of falsified samples of chloroquine (CQ) tablets. Analysis was carried out according to the U.S. Pharmacopeia[13]; see Supplementary Information for details of the analytical procedure. Ref = CQ authentic reference substance; I, II, III, IV, and V = falsified samples of CQ tablets (see Figure 1, Table 1).