| Literature DB >> 32398161 |
Åsa Holmner1,2, Fredrik Öhberg1, Urban Wiklund1, Eva Bergmann3, Anders Blomberg3, Karin Wadell4,5.
Abstract
BACKGROUND: Many telehealth systems have been designed to identify signs of exacerbations in patients with chronic obstructive pulmonary disease (COPD), but few previous studies have reported the nature of recorded lung function data and what variations to expect in this group of individuals. The aim of the study was to evaluate the nature of individual diurnal, day-to-day and long-term variation in important prognostic markers of COPD exacerbations by employing a telehealth system developed in-house.Entities:
Keywords: COPD; Exacerbations; Home-monitoring; Long-term variations; Spirometry; Telehealth
Mesh:
Year: 2020 PMID: 32398161 PMCID: PMC7218552 DOI: 10.1186/s12911-020-1103-6
Source DB: PubMed Journal: BMC Med Inform Decis Mak ISSN: 1472-6947 Impact factor: 2.796
Baseline characteristics of study subjects
| Sex (f/m) 8/3 | Baseline | |
|---|---|---|
| Median | IQR | |
| 67 | 59–72 | |
| 1.66 | 1.59–1.76 | |
| 65 | 59–87 | |
| 26 | 21–30 | |
| 2.70 | 2.6–3.9 | |
| 112 | 89–119 | |
| 2.15 | 1.8–3.0 | |
| 80 | 75–82 | |
| 1.01 | 0.9–1.7 | |
| 53 | 36–63 | |
| 54 | 38–62 | |
| 1.89 | 1.6–2.5 | |
| 98 | 82–106 | |
| 387 | 335–479 | |
| 96 | 95–98 | |
| 2 | 1.5–4 | |
BMI Body Mass Index, VC Vital Capacity, FVC Forced Vital Capacity, FEV Forced Expiratory Volume in one second, IC Inspiratory Capacity, 6MWT 6 min walking test, SpO Oxygen saturation measured by pulse oximetry, mMRC modified Medical Research Council Dyspnea Scale, IQR Inter Quartile Range (25–75), pred predicted, best of two tests
Monthly averages of FEV1 compared to measurements at the baseline examination
| 1 | 1.70 | 0.85 | 0.82 | 0.79 | 0.92 | 0.85 |
| 2 | 3.48 | 1.01 | 0.54 | 0.77 | 0.58 | 0.77 |
| 3 | 2.43 | 0.85 | 0.97 | 0.99 | 0.99 | 1.04 |
| 4 | 1.79 | 0.95 | 0.84 | 0.91 | 0.75 | 0.84 |
| 5 | 1.89 | 0.7 | 1.03 | 0.83 | 1.10 | 0.84 |
| 6 | 1.95 | 1.21 | 0.81 | 0.79 | 0.83 | 0.78 |
| 7 | 2.89 | 1.76 | 0.86 | 0.90 | 0.87 | 0.90 |
| 8 | 2.57 | 0.54 | 0.89 | 0.99 | 0.84 | 0.97 |
| 9 | 3.00 | 2.04 | 0.97 | 0.89 | 0.81 | 0.79 |
| 10 | 2.55 | 1.68 | 0.66 | 0.63 | 0.67 | 0.65 |
| 11 | 3.25 | 2.05 | 0.88 | 0.77 | 0.76 | 0.77 |
| Mean (SD) | 2.50 (0.61) | 1.24 (0.55) | 0.84 (0.14) | 0.84 (0.11) | 0.83 (0.14) | 0.84 (0.11) |
Values of home measurements are expressed as the ratio Home/Baseline (), where Home is the monthly average of AM and PM measurements, respectively
Monthly averages of IC compared to measurements at the baseline examination
| Subject | Predicted value (L) | Baseline (L) | Home | Home | ||
|---|---|---|---|---|---|---|
| AM | PM | AM | PM | |||
| 1 | 1.67 | 1.64 | 0.87 | 0.88 | 0.84 | 0.83 |
| 2 | 2.58 | 1.65 | 0.70 | 0.90 | 0.74 | 0.96 |
| 3 | 2.03 | 1.58 | 0.83 | 0.82 | 0.87 | 0.91 |
| 4 | 1.77 | 1.89 | 0.81 | 0.83 | 0.75 | 0.83 |
| 5 | 1.52 | 1.47 | 0.84 | 0.76 | 0.94 | 0.81 |
| 6 | 1.78 | 1.37 | 0.79 | 0.80 | 0.87 | 0.87 |
| 7 | 2.58 | 2.22 | 0.58 | 0.62 | 0.79 | 0.81 |
| 8 | 2.35 | 2.33 | 0.74 | 0.77 | 0.78 | 0.83 |
| 9 | 3.05 | 3.29 | 0.65 | 0.63 | 0.58 | 0.57 |
| 10 | 2.50 | 2.62 | 0.72 | 0.68 | 0.65 | 0.60 |
| 11 | 3.34 | 3.57 | 0.94 | 0.90 | 0.98 | 0.95 |
| Mean (SD) | 2.29 (0.59) | 2.15 (0.74) | 0.77 (0.11) | 0.78 (0.10) | 0.80 (0.12) | 0.82 (0.13) |
Values of home measurements are expressed as the ratio Home/Baseline (), where Home is the monthly average of AM and PM measurements, respectively
Correlation between prognostic markers of COPD exacerbations (spirometry, CAT and SpO2)
| Subject | FEV | IC vs CAT | FEV | IC vs SpO | FEV |
|---|---|---|---|---|---|
| 1 | 0.48 | −0.04 | −0.14 | 0.22 | 0.20 |
| 2 | 0.90 | −0.15 | −0.20 | 0.14 | 0.15 |
| 3 | 0.45 | −0.06 | −0.01 | 0.03 | 0.04 |
| 4 | 0.60 | −0.19 | −0.18 | −0.01 | 0.07 |
| 5 | 0.66 | 0.03 | 0.08 | − 0.16 | 0.07 |
| 6 | 0.44 | −0.16 | − 0.19 | − 0.01 | 0.10 |
| 7 | −0.03 | − 0.13 | 0.13 | − 0.19 | 0.09 |
| 8 | 0.42 | −0.35 | 0.12 | 0.20 | 0.31 |
| 9 | 0.53 | −0.47 | − 0.41 | −0.03 | − 0.06 |
| 10 | 0.58 | −0.42 | −0.15 | − 0.03 | −0.28 |
| 11 | 0.29 | −0.58 | 0.18 | 0.21 | −0.08 |
| Median (IQR) | 0.48 (0.17) | −0.16 (0.32) | −0.14 (0.30) | − 0.01 (0.22) | 0.07 (0.17) |
Values are correlation coefficients. FEV Forced Expiratory Volume in one second, IC Inspiratory Capacity, CAT COPD Assessment Test, SpO Oxygen saturation measured by pulse oximetry, IQR Inter Quartile Range
Fig. 1Weekly means of FEV1 (% of predicted), IC (% of predicted), SpO2 and CAT. Boxes show median and IQR, whiskers show range. Solid lines show the corresponding measurements from the baseline spirometry before the start of home monitoring. FEV: Forced Expiratory Volume in one second, IC: Inspiratory Capacity, SpO2: Oxygen saturation measured by pulse oximetry, CAT: COPD Assessment Test
Fig. 2Relative density of the changes in of FEV1 (left) and IC (right) between measurements (top), between successive AM measurements (middle), and between successive PM measurements (bottom). Thin lines show individual curves. Red thick lines show the averaged density curve. FEV: Forced Expiratory Volume in one second, IC: Inspiratory Capacity