Literature DB >> 32396067

Reaction Force Mapping by 3-Axis Tactile Sensing With Arbitrary Angles for Tissue Hard-Inclusion Localization.

Tianliang Li, Anqi Pan, Hongliang Ren.   

Abstract

Although robot-assisted diagnosis and minimally invasive surgery (MIS) brings distinct benefits, deficient multi-dimensional force feedback remains a noteworthy limitation and challenge in MIS. Aiming for a comprehensive high-fidelity perception of tissue-instrument interactions, we present a Fiber Bragg Grating (FBG)-based 3-axis tactile sensing for surface reaction force mapping, identification and localization of tissue hard-inclusion. The tactile sensing probe consists of five optical fibers inscribed with FBGs and a force-sensitive 3D printed deformable body. All fibers are suspended inside the deformable body in a parallel manner, leading to the direct compression or tension of each FBG. Such configuration can effectively avoid the chirping failure of FBG compared with the pasting FBG-based sensors. A linearized difference model is proposed to calibrate the 3-axis force detection and enhance the resistance to nonlinear interferences. Hard-inclusion identification experiments with varied hard-inclusion sizes and depths have been implemented through discrete palpation and dragging palpation modes. Results indicate that the probe can effectively identify the presence and location of these small hard-inclusions from the force mapping. Furthermore, lengthy vessels embedded in the phantom can be accurately identified through dragging palpation with an arbitrary contact angle. Another novelty of the probe is the reconstruction of the surface profile of a non-planar tissue, which further allows hard-inclusion identification and 3D localization. Ex-vivo tissue palpation on a porcine kidney further validates the effectiveness and feasibility of the probe to map surface reaction forces and localize the hard-inclusions intraoperatively.

Entities:  

Mesh:

Year:  2020        PMID: 32396067     DOI: 10.1109/TBME.2020.2991209

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  2 in total

1.  Origami-Inspired Structure with Pneumatic-Induced Variable Stiffness for Multi-DOF Force-Sensing.

Authors:  Wenchao Yue; Jiaming Qi; Xiao Song; Shicheng Fan; Giancarlo Fortino; Chia-Hung Chen; Chenjie Xu; Hongliang Ren
Journal:  Sensors (Basel)       Date:  2022-07-19       Impact factor: 3.847

2.  A Piezoelectric Tactile Sensor for Tissue Stiffness Detection with Arbitrary Contact Angle.

Authors:  Yingxuan Zhang; Feng Ju; Xiaoyong Wei; Dan Wang; Yaoyao Wang
Journal:  Sensors (Basel)       Date:  2020-11-18       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.