Shear wave elastography in diffuse thyroid disease.

Zuzana Sedlackova1, Jan Herman2, Tomas Furst1, Richard Salzman2, Jaromir Vachutka3, Miroslav Herman1.   

Abstract

AIM: Our aim was to examine the contribution of shear wave elastography to ultrasonographic assessment in diffuse thyroid disease, specifically to evaluate the stiffness of the thyroid gland in diffuse thyroid disease and compare it with healthy controls.
METHODS: A total of 46 patients with diffuse thyroid disease were examined clinically, by conventional ultrasound, and shear wave elastography. The conventional ultrasound parameters followed were: volume, margin quality, presence of nodules, and vascularisation. We measured the mean, minimum, and maximum stiffnesses by shear wave elastography. Results were correlated with values in 128 healthy subjects.
RESULTS: Patients with diffuse thyroid disease had significantly higher mean and maximal stiffnesses of the thyroid gland: 12.5 ± 5 kPa and 35.3 ± 12.8 kPa, respectively, and lower minimal stiffness: 0.5 ± 0.6 kPa than the healthy control group with mean, maximal, and minimal values of 9.5 ± 3.6 kPa, 22.5 ± 7.3 kPa, and 2.2 ± 2.1 kPa (P<0.001). Stiffness values were positively correlated with BMI and volume of the thyroid; they did not correlate with margin quality, presence of nodules nor vascularisation. Compared with healthy volunteers, thyroid glands of patients with diffuse thyroid disease had a blurred margin more frequently and the amount of nodules and vascularisation were higher. Patients with Graves-Basedow disease did not have significantly different mean, maximal, nor minimal stiffnesses than those with thyroiditis.
CONCLUSION: Both mean and maximal stiffness of the thyroid gland are significantly higher in diffuse thyroid disease than in the healthy population, while minimal stiffness is lower.

Entities:  

Keywords:  diffuse thyroid disease; elastography; shear wave; ultrasound

Mesh:

Year:  2020        PMID: 32394978     DOI: 10.5507/bp.2020.018

Source DB:  PubMed          Journal:  Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub        ISSN: 1213-8118            Impact factor:   1.245


  1 in total

1.  Evaluation of Ultrasound Elastography Combined With Chi-Square Automatic Interactive Detector in Reducing Unnecessary Fine-Needle Aspiration on TIRADS 4 Thyroid Nodules.

Authors:  Xiao Liu; Li Xie; Xianjun Ye; Yayun Cui; Nianan He; Lei Hu
Journal:  Front Oncol       Date:  2022-02-16       Impact factor: 6.244

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.