| Literature DB >> 32393137 |
Shuang-Long Hu1, Chun-Xin Wang2, Hui-Jun Lu1, Ye Yuan1.
Abstract
OBJECTIVE: To evaluate the feasibility, safety, and efficacy of an accurate kissing Viabahn stent technique to manage injuries near the innominate artery bifurcation.Entities:
Keywords: Innominate artery; accurate kissing Viabahn stent technique; brachiocephalic artery; endovascular repair; right common carotid artery; right subclavian artery
Mesh:
Year: 2020 PMID: 32393137 PMCID: PMC7221169 DOI: 10.1177/0300060520912104
Source DB: PubMed Journal: J Int Med Res ISSN: 0300-0605 Impact factor: 1.671
Figure 1.Representative images showing: (A) Three-dimensional reconstruction of the aortic arch by computed tomography angiography (CTA) revealing a pseudoaneurysm at the innominate artery bifurcation; (B) Intraoperative aortic arch angiography confirming that the bleeding point was at the innominate artery bifurcation; (C) The accurate kissing Viabahn stent technique used to cover the bleeding points, revealing no subsequent bleeding or endoleak; and (D) Postoperative follow-up CTA three-dimensional reconstruction of the aortic arch showing that the stent was patent without endoleak or displacement.
Summary of demographic and clinical data for the 10 included patients who underwent an accurate kissing Viabahn stent technique.
| Case No. | Parameter | |||||||
|---|---|---|---|---|---|---|---|---|
| Sex | Age, years | Injured vessels | Distance between injury site and BIA, cm | Medical history | Graft dimensions (CCA, RSA), mm | Cause of IA injury | Diameter of IA, mm | |
| 1 | M | 51 | IA | 0.5 | RF, ↑BP, DM | 8 × 100, 10 × 100 | Iatrogenic injury | 10 |
| 2 | M | 77 | IA | 0.5 | RF, ↑BP, CAHD | 8 × 100, 10 × 100 | Iatrogenic injury | 9 |
| 3 | F | 50 | BIA | 0 | RF, ↑BP | 8 × 100, 10 × 100 | Iatrogenic injury | 10 |
| 4 | F | 67 | BIA | 0 | RF, ↑BP, CAHD | 8 × 100, 10 × 100 | Iatrogenic injury | 10 |
| 5 | M | 25 | BIA | 0 | – | 8 × 100, 10 × 100 | trauma | 10 |
| 6 | M | 50 | BIA | 0 | RF | 8 × 100, 10 × 100 | Iatrogenic injury | 9 |
| 7 | M | 50 | BIA | 0 | RF, ↑BP, DM | 8 × 100, 10 × 100 | Iatrogenic injury | 9 |
| 8 | F | 55 | RCCA | 1.0 | RF | 8 × 100, 10 × 100 | Iatrogenic injury | 9 |
| 9 | M | 56 | RCCA | 0.5 | ↑BP | 8 × 100, 10 × 100 | trauma | 10 |
| 10 | F | 47 | RSA | 0.8 | ↑BP | 8 × 100, 10 × 100 | trauma | 10 |
M, male; F, female; IA, innominate artery; BIA, bifurcation of the IA; RCCA, right common carotid artery; RSA, right subclavian artery; RF, renal failure; ↑BP, hypertension; CAHD, coronary atherosclerotic heart disease; CCA, common carotid artery; DM, diabetes mellitus.
Summary of outcomes in 10 patients who underwent an accurate kissing Viabahn stent technique.
| Case no. | Immediate outcome | Early postoperative outcome | Duration of postoperative hospitalization (days) | 3-month Doppler ultrasound | 6-month CT follow-up | 1-year CT follow-up | 2-year CT follow-up | Follow-up duration (months) |
|---|---|---|---|---|---|---|---|---|
| 1 | Complete exclusion | Uneventful | 7 | Patency | Stents in good position | Stents in good position | Stents in good position | 24 |
| 2 | Complete exclusion | Uneventful | 5 | Patency | Stents in good position | Stents in good position | – | 12 |
| 3 | Small Type I endoleak | Uneventful | 8 | Patency | Stents in good position, small residual Type I endoleak | Stents in good position, endoleak disappeared, | Stents in good position | 24 |
| 4 | Complete exclusion | Uneventful | 6 | Patency | Stents in good position | Stents in good position | Declined further follow-up | 12 |
| 5 | Small Type I endoleak | Uneventful | 9 | Patency | Stents in good position, small residual Type I endoleak | Stents in good position, small residual Type I endoleak | Stents in good position, endoleak disappeared | 24 |
| 6 | Complete exclusion | Uneventful | 7 | Patency | Stents in good position | Stents in good position | – | 12 |
| 7 | Complete exclusion | Uneventful | 6 | Patency | Stents in good position | Stents in good position | – | 12 |
| 8 | Complete exclusion | Uneventful | 5 | Patency | Stents in good position | Stents in good position | – | 12 |
| 9 | Complete exclusion | Uneventful | 4 | Patency | Stents in good position | Stents in good position | – | 12 |
| 10 | Complete exclusion | Uneventful | 6 | Patency | Stents in good position | Stents in good position | Stents in good position | 24 |
CT, computed tomography.