Literature DB >> 32389729

Concurrent electrophysiological and hemodynamic measurements of evoked neural oscillations in human visual cortex using sparsely interleaved fast fMRI and EEG.

Hsin-Ju Lee1, Shu-Yu Huang2, Wen-Jui Kuo2, Simon J Graham1, Ying-Hua Chu1, Matti Stenroos3, Fa-Hsuan Lin4.   

Abstract

Electroencephalography (EEG) concurrently collected with functional magnetic resonance imaging (fMRI) is heavily distorted by the repetitive gradient coil switching during the fMRI acquisition. The performance of the typical template-based gradient artifact suppression method can be suboptimal because the artifact changes over time. Gradient artifact residuals also impede the subsequent suppression of ballistocardiography artifacts. Here we propose recording continuous EEG with temporally sparse fast fMRI (fast fMRI-EEG) to minimize the EEG artifacts caused by MRI gradient coil switching without significantly compromising the field-of-view and spatiotemporal resolution of fMRI. Using simultaneous multi-slice inverse imaging to achieve whole-brain fMRI with isotropic 5-mm resolution in 0.1 ​s, and performing these acquisitions once every 2 ​s, we have 95% of the duty cycle available to record EEG with substantially less gradient artifact. We found that the standard deviation of EEG signals over the entire acquisition period in fast fMRI-EEG was reduced to 54% of that in conventional concurrent echo-planar imaging (EPI) and EEG recordings (EPI-EEG) across participants. When measuring 15-Hz steady-state visual evoked potentials (SSVEPs), the baseline-normalized oscillatory neural response in fast fMRI-EEG was 2.5-fold of that in EPI-EEG. The functional MRI responses associated with the SSVEP delineated by EPI and fast fMRI were similar in the spatial distribution, the elicited waveform, and detection power. Sparsely interleaved fast fMRI-EEG provides high-quality EEG without substantially compromising the quality of fMRI in evoked response measurements, and has the potential utility for applications where the onset of the target stimulus cannot be precisely determined, such as epilepsy.
Copyright © 2020 The Author(s). Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Fast MRI; Gradient artifact; Inverse imaging; Steady-state visual evoked potential

Mesh:

Year:  2020        PMID: 32389729     DOI: 10.1016/j.neuroimage.2020.116910

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  1 in total

1.  Ballistocardiogram suppression in concurrent EEG-MRI by dynamic modeling of heartbeats.

Authors:  Hsin-Ju Lee; Simon J Graham; Wen-Jui Kuo; Fa-Hsuan Lin
Journal:  Hum Brain Mapp       Date:  2022-06-13       Impact factor: 5.399

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.