Percutaneous tracheostomy in patients with COVID-19: sealing the bronchoscope with an in-line suction sheath.

Chadwan Al Yaghchi1, Catriona Ferguson2, Guri Sandhu2.   

Abstract

Entities:  

Keywords:  COVID-19; aerosol-generating procedure; bronchoscopy; percutaneous tracheostomy; tracheostomy

Mesh:

Year:  2020        PMID: 32386837      PMCID: PMC7184020          DOI: 10.1016/j.bja.2020.04.068

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


× No keyword cloud information.
Editor—Tracheostomy represents a particular challenge during the coronavirus disease 2019 (COVID-19) pandemic in patients infected with SARS-CoV-2. It is an aerosol-generating procedure with significant infection risk to surgeons, anaesthetists, and theatre staff. Open surgical tracheostomy and percutaneous dilation tracheostomy have differences in terms of aerosol generation. While the choice of technique is beyond the scope of this letter, the surgeon or intensivist performing the tracheostomy should use the technique with which they are most accustomed to reduce risk. Early on percutaneous dilation tracheostomy was performed using multiple sequential dilators over a guidewire. Over the years, two major advances were introduced: use of a single dilator and use of an intubating bronchoscope down the tracheal tube. The latter is, in our view, an indispensable tool to allow safe percutaneous dilation tracheostomy. The bronchoscope allows visualisation of the needle, its correct positioning in the midline, and avoidance of the posterior tracheal wall, injury of which can lead to false passages and tracheoesophageal fistula with potentially disastrous consequences. The main drawback to using a bronchoscope in COVID-19 patients is the increased risk of aerosolisation from the insertion point of the bronchoscope at the tracheal tube connection (catheter mount with suction window). We describe a closed, in-line suction system to seal the bronchoscope and reduce the risk to operators and staff. Our technique utilises the sheath of a 12F closed in-line suction system (Halyard Health Inc, Atlanta, GA, USA). The sheath needs to be circumferentially cut at the suction-valve end of the system (Fig 1 a) with particular attention paid to maintain integrity of the sheath. The suction catheter is removed (Fig. 1b and c) and a single use videobronchoscope (Ambu® aScope™, Ambu A/S, Ballerup, Denmark) is advanced through the sheath and the one-way valve. The sheath is then tightly taped around the proximal end of the bronchoscope shaft using a Tegaderm™ (3M Healthcare, Neuss, Germany) film dressing or similar tape (Fig 1d). Length and mobility of the sheathed segment of the bronchoscope need to take into account the length of the tracheal tube, and this can be tested using an identical tracheal tube away from the patient (Fig 1e). The anaesthetist is asked to withdraw the tracheal tube until the cuff sits at or just below the glottis so as to avoid cuff puncture and to reduce duration of the procedure. This should be performed using a videolaryngoscope to protect the anaesthetist from aerosol. The patient should be pre-oxygenated and the ventilator turned off allowing enough time for passive expiration via an open adjustable pressure-limiting valve. The catheter mount can then be replaced with the mounted bronchoscope and the ventilator connected via the side port. Ventilation can commence until the start of the percutaneous dilation tracheostomy procedure. To minimise the period during which aerosol might be generated, we perform a small skin incision before needle insertion.
Fig 1

Stepwise demonstration of in-line suction system to seal the bronchoscope during percutaneous tracheostomy.

Stepwise demonstration of in-line suction system to seal the bronchoscope during percutaneous tracheostomy. We believe our modification offers an extra level of safety, not only for the operator of the bronchoscope, but other staff present during the procedure.

Declarations of interest

The authors declare that they have no conflicts of interest.
  2 in total

Review 1.  Tracheotomy complications: a retrospective study of 1130 cases.

Authors:  D Goldenberg; E G Ari; A Golz; J Danino; A Netzer; H Z Joachims
Journal:  Otolaryngol Head Neck Surg       Date:  2000-10       Impact factor: 3.497

Review 2.  Percutaneous tracheostomy: a comprehensive review.

Authors:  Ashraf O Rashid; Shaheen Islam
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

  2 in total
  3 in total

1.  The human factor in critical decision making.

Authors:  R Blasco Mariño; F Clau Terré; F Landucci; A Biarnes-Suñé
Journal:  Rev Esp Anestesiol Reanim (Engl Ed)       Date:  2022-05-27

2.  Percutaneous Tracheostomy in COVID-19 Patients: A Four-step Safe Protocol.

Authors:  Prashant Nasa; Aanchal Singh; Alaeldin Ali; Saroj Patidar; Annamma Georgian
Journal:  Indian J Crit Care Med       Date:  2020-09

3.  [The human factor in critical decision making].

Authors:  R Blasco Mariño; F Clau Terré; F Landucci; A Biarnes-Suñé
Journal:  Rev Esp Anestesiol Reanim       Date:  2022-01-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.