Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical area.

E M Gowans1, P Hyltoft Petersen, O Blaabjerg, M Hørder.   

Abstract

Analytical goals required for the successful transfer of reference intervals between laboratories within a specified limited geographical area, with a population homogeneous for the quantities, are presented. Diagrams are shown which allow the investigation of the influence of analytical imprecision and bias, both separately and in combination, on the percentage of the population outside each reference limit. Figures to evaluate the effect of population sample size on the size of confidence interval around each reference limit are combined with the diagrams for analytical imprecision and bias. The maximum acceptable percentage of the population outside the limit for the 0.90 confidence interval of each of the means +/- 1.96 s reference limits is 4.6% for a population sample size of 120. Based on this, the maximum acceptable imprecision, with no bias, is 0.6 of the total biological standard deviation (sB) and the maximum acceptable bias, with no imprecision, is 0.25 sB.

Mesh:

Year:  1988        PMID: 3238321     DOI: 10.3109/00365518809088757

Source DB:  PubMed          Journal:  Scand J Clin Lab Invest        ISSN: 0036-5513            Impact factor:   1.713


  8 in total

1.  Prerequisites for use of common reference intervals.

Authors:  Ferruccio Ceriotti
Journal:  Clin Biochem Rev       Date:  2007-08

2.  Analytical quality goals for 25-vitamin D based on biological variation.

Authors:  Adie Viljoen; Dhruv K Singh; Ken Farrington; Patrick J Twomey
Journal:  J Clin Lab Anal       Date:  2011       Impact factor: 2.352

Review 3.  Challenges and Lessons Learned in Generating and Interpreting NHANES Nutritional Biomarker Data.

Authors:  Christine M Pfeiffer; David A Lacher; Rosemary L Schleicher; Clifford L Johnson; Elizabeth A Yetley
Journal:  Adv Nutr       Date:  2017-03-15       Impact factor: 8.701

4.  Whether western normative laboratory values used for clinical diagnosis are applicable to Indian population? An overview on reference interval.

Authors:  T Malati
Journal:  Indian J Clin Biochem       Date:  2009-07-09

5.  Standardised Resting Time Prior to Blood Sampling and Diurnal Variation Associated with Risk of Patient Misclassification: Results from Selected Biochemical Components.

Authors:  Ida B Andersen; Claus L Brasen; Henry Christensen; Lene Noehr-Jensen; Dorthe E Nielsen; Ivan Brandslund; Jonna S Madsen
Journal:  PLoS One       Date:  2015-10-13       Impact factor: 3.240

Review 6.  Biological variation: Understanding why it is so important?

Authors:  Tony Badrick
Journal:  Pract Lab Med       Date:  2021-01-04

7.  Hormone Levels and Sexual Functioning After Risk-Reducing Salpingo-Oophorectomy.

Authors:  Nora Johansen; Astrid H Liavaag; Lars Mørkrid; Trond M Michelsen
Journal:  Sex Med       Date:  2018-04-07       Impact factor: 2.491

8.  Optimal Analytical Performance for POCT.

Authors:  Callum G Fraser
Journal:  EJIFCC       Date:  2001-04-05