Literature DB >> 32377914

Pneumothorax and pulmonary hemorrhage after CT-guided lung biopsy: incidence, clinical significance and correlation.

Vittorio Sabatino1, Umberto Russo1, Fabiano D'Amuri1, Andrea Bevilacqua1, Francesco Pagnini1, Gianluca Milanese1, Francesco Gentili2, Rita Nizzoli3, Marcello Tiseo3, Giuseppe Pedrazzi4, Massimo De Filippo1.   

Abstract

OBJECTIVES: To evaluate the incidence and clinical significance of pneumothorax (PTX) and pulmonary hemorrhage (PH) after CT-guided lung biopsy (CT-LB). To test correlations of PTX and chest tube insertion (CTI) with PH and other imaging and procedural parameters.
METHODS: Pre-procedural CT and CT-LB scans of 904 patients were examined. Incidence of PTX and PH and PH location (type-1 along needle track; type-2 perilesional) and severity according to its thickness (low grade < 6 mm; high grade > 6 mm) were recorded. PTX was considered clinically significant if treated with CTI, PH if treated with endoscopic/endovascular procedure. Binary logistic regression analyses were used to determine the effects of different imaging and procedural parameters on the likelihood to develop PTX, CTI and PH and to define their correlation.
RESULTS: PTX occurred in 306/904 cases (33.8%); CTI was required in 18/306 (5.9%). PH occurred in 296/904 cases (32.7%), and no case required treatment. Nodule-to-pleura distance (ORPTX = 1.052; ORCTI = 1.046; ORPH 1.077), emphysema (ORPTX = 1.287; ORPH = 0.573), procedure time (ORPTX = 1.019; ORCTI = 1.039; ORPH = 1.019), target size (ORPTX = 0.982; ORPH = 0.968) and needle gauge (ORPTX = 0.487; ORCTI = 4.311; ORPH = 2.070) showed statistically significant correlation to PTX, CTI and PH. Type-1 PH showed a protective effect against PTX and CTI (ORPTX = 0.503; ORCTI = 0.416).
CONCLUSION: PTX and PH have similar incidence after CT-guided lung biopsy. PH along needle track may represent a protective factor against development of PTX and against PTX requiring CTI.

Entities:  

Keywords:  Biopsy, fine needle; Biopsy, large-core needle; Hemorrhage; Image-guided biopsy; Pneumothorax

Year:  2020        PMID: 32377914     DOI: 10.1007/s11547-020-01211-0

Source DB:  PubMed          Journal:  Radiol Med        ISSN: 0033-8362            Impact factor:   3.469


  2 in total

1.  Computed tomography-guided lung biopsy: Association between biopsy needle angle and pneumothorax development.

Authors:  Takumi Kuriyama; Katsuhiro Masago; Yuki Okada; Nobuyuki Katakami
Journal:  Mol Clin Oncol       Date:  2017-11-27

2.  Incidental and Underreported Pleural Plaques at Chest CT: Do Not Miss Them-Asbestos Exposure Still Exists.

Authors:  Maria Antonietta Mazzei; Francesco Contorni; Francesco Gentili; Susanna Guerrini; Francesco Giuseppe Mazzei; Antonio Pinto; Nevada Cioffi Squitieri; Antonietta Gerardina Sisinni; Valentina Paolucci; Riccardo Romeo; Pietro Sartorelli; Luca Volterrani
Journal:  Biomed Res Int       Date:  2017-06-05       Impact factor: 3.411

  2 in total
  5 in total

Review 1.  Pneumothorax Induced by Computed Tomography Guided Transthoracic Needle Biopsy: A Review for the Clinician.

Authors:  Lichuan Zeng; Huaqiang Liao; Fengchun Ren; Yudong Zhang; Qu Wang; Mingguo Xie
Journal:  Int J Gen Med       Date:  2021-03-23

2.  Augmented reality 3D navigation system for percutaneous CT-guided pulmonary ground-glass opacity biopsies: a comparison with the standard CT-guided technique.

Authors:  Eliodoro Faiella; Laura Messina; Gennaro Castiello; Caterina Bernetti; Giuseppina Pacella; Carlo Altomare; Flavio Andresciani; Marina Sarli; Filippo Longo; Pierfilippo Crucitti; Bruno Beomonte Zobel; Rosario Francesco Grasso
Journal:  J Thorac Dis       Date:  2022-02       Impact factor: 2.895

Review 3.  Precision Imaging Guidance in the Era of Precision Oncology: An Update of Imaging Tools for Interventional Procedures.

Authors:  Chiara Floridi; Michaela Cellina; Giovanni Irmici; Alessandra Bruno; Nicolo' Rossini; Alessandra Borgheresi; Andrea Agostini; Federico Bruno; Francesco Arrigoni; Antonio Arrichiello; Roberto Candelari; Antonio Barile; Gianpaolo Carrafiello; Andrea Giovagnoni
Journal:  J Clin Med       Date:  2022-07-12       Impact factor: 4.964

4.  Application of rapid on‑site evaluation in computed tomography‑guided percutaneous transthoracic needle biopsy of pulmonary nodules of ≤2.0 cm in diameter.

Authors:  Dongxu Wang; Qing Zhang; Yuguang Wang; Wei Dou; Guoxu Ding; Qiuting Wen; Ying Han; Youli Du; Bo Li
Journal:  Exp Ther Med       Date:  2022-09-07       Impact factor: 2.751

5.  Clinical Value of CT-Guided Fine Needle Aspiration and Tissue-Core Biopsy of Thoracic Masses in the Dog and Cat.

Authors:  Massimo Vignoli; Roberto Tamburro; Andrea Felici; Francesca Del Signore; Annalisa Dettori; Morena Di Tommaso; Angela Ghiraldelli; Rossella Terragni; Francesco Simeoni; Ilaria Falerno; Arianna Miglio
Journal:  Animals (Basel)       Date:  2021-03-19       Impact factor: 2.752

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.