Literature DB >> 32377823

XEN-augmented Baerveldt drainage device implantation in refractory glaucoma: 1-year outcomes.

Giorgio Enrico Bravetti1, Kaweh Mansouri2,3, Kevin Gillmann2, Harsha L Rao4, André Mermoud2.   

Abstract

PURPOSE: To evaluate outcomes of XEN-augmented Baerveldt drainage device implantation in refractory glaucoma and factors predicting surgical success.
METHOD: All eyes undergoing XEN-augmented Baerveldt for refractory open-angle glaucoma at a tertiary glaucoma centre between January 2016 and November 2017 were retrospectively enrolled. Intraocular pressure (IOP), number of anti-glaucomatous medications and postoperative adverse events (AEs) were analysed for 1 year postoperatively. Surgical success was defined as achieving (1) an IOP ≤ 15 mmHg or (2) ≤ 18 mmHg, with or without (qualified) or without medications (complete). Any subsequent glaucoma surgery was considered failure.
RESULTS: Out of 60 eyes enrolled, 12-month data were available for 41 eyes (71.4%). Mean age was 64.7 ± 23.1 years (50% female). Following surgery, IOP decreased significantly from a baseline of 29.9 ± 13.2 to 15.2 ± 6.6 mmHg (- 49.2%; P < 0.0001) at 12 months. Anti-glaucoma medications decreased from 3.0 ± 1.3 to 1.3 ± 0.9. Complete success was achieved by 14.6% of eyes using both the ≤ 15 mmHg and the ≤ 18 mmHg thresholds, and qualified success was achieved in 43.9% and 48.8%, respectively. Throughout the follow-up period, AEs were observed in 51.2% (hypotony = 24.4%; XEN blockage = 17.1%; displacement of XEN gel stent = 4.9%; hyphema = 4.9%). The 12-month success rate was significantly higher in patients who presented an IOP ≤ 10 mmHg at 1 week (58.6%, P = 0.001). Overall, 41.5% of patients required reoperation at 12 months (58.8% revision of the surgery; 41.2% transscleral cyclodestruction).
CONCLUSION: XEN-augmented Baerveldt is a safe and moderately effective technique to reduce IOP and anti-glaucoma medications in refractory glaucoma. IOP at 1 week seems to be a predictor for surgical success. Nevertheless, a high proportion of patients requires reoperation.

Entities:  

Keywords:  Baerveldt’s tube; Glaucoma; Glaucoma drainage devices; Glaucoma surgery; XEN gel stent

Mesh:

Year:  2020        PMID: 32377823     DOI: 10.1007/s00417-020-04654-3

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  3 in total

1.  The Outcomes of XEN Gel Stent Implantation: A Systematic Review and Meta-Analysis.

Authors:  Xuan-Zhu Chen; Zhi-Qiao Liang; Kang-Yi Yang; Kun Lv; Yao Ma; Meng-Yang Li; Hui-Juan Wu
Journal:  Front Med (Lausanne)       Date:  2022-02-04

2.  The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis.

Authors:  Xiang Yang; Yang Zhao; Yu Zhong; Xuanchu Duan
Journal:  BMC Ophthalmol       Date:  2022-07-15       Impact factor: 2.086

3.  Outcomes of Deep Sclerectomy following Failed XEN Gel Stent Implantation in Open-Angle Glaucoma: A Prospective Study.

Authors:  Giorgio Enrico Bravetti; Kevin Gillmann; Harsha L Rao; André Mermoud; Kaweh Mansouri
Journal:  J Clin Med       Date:  2022-08-16       Impact factor: 4.964

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.