Literature DB >> 32371125

Repeatability and Reproducibility of Photoreceptor Density Measurement in the Macula Using the Spectralis High Magnification Module.

Luísa S M Mendonça1, Phillip X Braun2, Sarah M Martin3, Alexander Hüther4, Nihaal Mehta5, Yi Zhao6, Omar Abu-Qamar3, Eleni K Konstantinou3, Caio V S Regatieri1, Andre J Witkin3, Caroline R Baumal3, Jay S Duker3, Nadia K Waheed7.   

Abstract

PURPOSE: To evaluate the repeatability and reproducibility of photoreceptor density assessment with manual cell counting in healthy participants imaged with the Heidelberg Spectralis High Magnification Module (HMM).
DESIGN: Precision study, evaluation of diagnostic test or technology. PARTICIPANTS: Eleven eyes of 8 participants.
METHODS: Images were acquired using the Spectralis HMM by a single operator during 2 separate imaging sessions. The 3 highest-quality images of each eye from each session were selected for analysis and coregistered. For a subset of participants, a second operator acquired images in 1 session, and images with the best quality were selected for analysis. Photoreceptor densities were obtained by manual counts in squares of 0.0625 mm2 located in the parafovea. Repeatability (intragrader and intrasession) and reproducibility (interoperator, intergrader, and intersession) were assessed by calculating the intraclass correlation coefficient (ICC) from linear mixed effects models. Bland-Altman plots, coefficients of repeatability, and Pearson correlation results were reported. MAIN OUTCOME MEASURES: Intragrader, intrasession, intersession, interoperator, and intergrader ICC estimates and their 95% confidence intervals for photoreceptor density measurements in the parafovea.
RESULTS: Twenty-four eyes of 13 healthy participants were imaged initially. Of these, 11 eyes (45.83%) of 8 participants that had at least 3 acceptable images in each session were included in this study. Mean parafoveal photoreceptor density was 14 988 cells/mm2 (standard deviation, 1403.15 cells/mm2). Intragrader ICC was 0.84 (95% confidence interval, 0.57-0.95), intrasession ICC was 0.69 (95% confidence interval, 0.17-0.86), intersession ICC was 0.88 (95% confidence interval, 0.53-0.96), interoperator ICC was 0.70 (95% confidence interval, 0-0.95), and intergrader ICC was 0.22 (95% confidence interval, 0-0.71).
CONCLUSIONS: Images obtained with the HMM allow for photoreceptor mosaic visualization in the macular area, mainly in the parafovea. Although densities obtained are in accordance with other reported methods in the literature, variability within and between images of the apparent cell mosaic were observed, and this study did not demonstrate high repeatability or reproducibility for quantitative assessments using the manual counting method.
Copyright © 2020 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2020        PMID: 32371125     DOI: 10.1016/j.oret.2020.04.021

Source DB:  PubMed          Journal:  Ophthalmol Retina        ISSN: 2468-6530


  4 in total

1.  Comparison of Cone Mosaic Metrics From Images Acquired With the SPECTRALIS High Magnification Module and Adaptive Optics Scanning Light Ophthalmoscopy.

Authors:  Niamh Wynne; Heather Heitkotter; Erica N Woertz; Robert F Cooper; Joseph Carroll
Journal:  Transl Vis Sci Technol       Date:  2022-05-02       Impact factor: 3.048

Review 2.  Promises and pitfalls of evaluating photoreceptor-based retinal disease with adaptive optics scanning light ophthalmoscopy (AOSLO).

Authors:  Niamh Wynne; Joseph Carroll; Jacque L Duncan
Journal:  Prog Retin Eye Res       Date:  2020-11-06       Impact factor: 19.704

3.  Ultrastructural study of closed macular hole- preliminary application of a novel high magnification module combining with OCT.

Authors:  Chang-Yu Qiu; Yuan-Yuan Shi; Hong-Wei Zhao; Chuang Nie; Ming-Xia Dong; Huai-Qiang Zhang; Jun Zhao; Qian-Qian Xu; Fei-Long Song; Xiao-Hua Guo; Lin Shi; Chang-Ying Liu; Yu-Bo Gong; Ling Luo
Journal:  BMC Ophthalmol       Date:  2021-03-22       Impact factor: 2.209

4.  Computer-assisted photoreceptor assessment on Heidelberg Engineering Spectralis™ High Magnification Module™ images.

Authors:  Timo W F Mulders; B Jeroen Klevering; Carel B Hoyng; Thomas Theelen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-08-06       Impact factor: 3.117

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.