Literature DB >> 32370908

Translucency, flexural strength, fracture toughness, fracture load of 3-unit FDPs, Martens hardness parameter and grain size of 3Y-TZP materials.

Nina Lümkemann1, Regina Pfefferle1, Eva Jerman1, Beatrice Sener2, Bogna Stawarczyk3.   

Abstract

OBJECTIVE: This investigation tested pre-shaded 3Y-TZP materials on optical, mechanical and structural properties and calculated correlations between these properties.
METHODS: Seven A2-shaded 3Y-TZP zirconia materials were investigated on translucency (T) via UV-vis-spectrophotometer, fracture load of 3-unit FDPs (FL), biaxial flexural strength (FS), Chevron-Notch Beam (CNB), fracture toughness (KIC) and Martens parameter (hardness: HM and indentation modulus: EIT). FL, FS and KIC were measured in a universal testing machine. The grain size was evaluated by scanning electron microscopy (SEM). Data was analyzed using one-way ANOVA followed by post hoc Scheffé, Kruskal-Wallis-, Mann-Whitney-U- and Pearson-test (p<0.05).
RESULTS: For translucency, negative correlations were found with results of facture load (R=-0.444, p<0.001) and KIC (R=-0.503, p<0.001). While a positive correlation was found between translucency and flexural strength (R=0.238, p=0.019), between fracture load and EIT (R=0.227, p<0.029), between fracture load and KIC (R=0.362, p<0.001) as well as between fracture load and the grain size (R=0.598, p=0.007). While the grain size positively correlated with EIT (R=0.534, p=0.017) as well as EIT with HM (R=0.720, p<0.001). SIGNIFICANCE: Despite of being based on the same raw material, tested zirconia materials significantly differed regarding optical, mechanical (except biaxial flexural strength and Martens hardness) and structural properties. Materials with highest optical properties were those with lowest mechanical properties (CER, COP).
Copyright © 2020 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Biaxial flexural strength; Fracture load; Grain size analysis; Indentation modulus; Martens hardness; Mechanical properties; Optical properties; Pre-shade zirconia; Translucency

Year:  2020        PMID: 32370908     DOI: 10.1016/j.dental.2020.03.027

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  1 in total

Review 1.  The influence of zirconia veneer thickness on the degree of conversion of resin-matrix cements: an integrative review.

Authors:  Christie M Tafur-Zelada; Oscar Carvalho; Filipe S Silva; Bruno Henriques; Mutlu Özcan; Júlio C M Souza
Journal:  Clin Oral Investig       Date:  2021-03-30       Impact factor: 3.573

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.