| Literature DB >> 32370523 |
Liepollo Ntlhakana1, Angie A Heliopoulos.
Abstract
BACKGROUND: Occupational activities performed by sound engineers are associated with hearing loss. However, there is a dearth of research on the hearing functions and the related hearing loss for sound engineers.Entities:
Keywords: hearing conservation programmes; hearing protection devices, sound engineers, decibels.; noise-induced hearing loss
Mesh:
Year: 2020 PMID: 32370523 PMCID: PMC7203214 DOI: 10.4102/sajcd.v67i1.638
Source DB: PubMed Journal: S Afr J Commun Disord ISSN: 0379-8046
Demographics of the study participants (N = 8).
| Item | Categories | |
|---|---|---|
| Age (years) | 21–25 | 3 |
| 26–30 | 4 | |
| 31–35 | 1 | |
| Race | Black African people | 1 |
| Mixed race people | 1 | |
| White people | 6 | |
| Gender | Female | 1 |
| Male | 7 | |
| Years of experience | 1–5 | 3 |
| 6–10 | 4 | |
| 11–15 | 0 | |
| 16–20 | 1 | |
| Education level | Tertiary | 8 |
Equipment used and procedures followed in the current study.
| Type of assessment | Hearing screening | Diagnostic audiometry |
|---|---|---|
| Equipment | Welch-Allyn Otoscope | Welch-Allyn Otoscope |
| MT-10 Immittance Meter for tympanometry and ipsilateral reflexes | MT-10 Immittance Meter for tympanometry and ipsilateral reflexes | |
| Audio-screener for air-conduction pure-tone | Interacoustics AC40 diagnostic audiometer | |
| Oto-acoustic emissions | Path Medical Solutions – Amtronix Diagnostics: Sentiero Electrophysiology machine | |
| Noise free | 16 hours | 16 hours |
| Who conducted the test | Audiologist | Audiologist |
, Researcher.
FIGURE 1Study participants’ symptomatology.
FIGURE 2Recreational noise exposure.
Hearing screening results ( = 8).
| Test | Equipment | Test findings | Left ear ( | Right ear ( |
|---|---|---|---|---|
| Otoscopic examination | Otoscope (Welch Allyn) | Impacted cerumen | 4 | 0 |
| Dull tympanic membrane | 1 | 2 | ||
| Tympanometry | MT10 (Inter-acoustics) | Pass | 4 | 6 |
| Refer | 4 | 2 | ||
| Acoustic reflexes | MT10 (Inter-acoustics) | Pass | 5 | 5 |
| Refer | 3 | 3 | ||
| DP oto-acoustic emissions | Path Sentiero | Pass | 8 | 8 |
| Pure tone testing | GSI Audiometer | Pass | 8 | 8 |
DP, distortion product; GSI, Grason-Stadler Inc.
Results from diagnostic audiological testing (N = 16 ears)
| Test | Test findings | Variable | Left ear (n = 8 ears) | Right ear ( | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Ipsilateral | Contralateral | Ipsilateral | Contralateral | |||||||||
| Present (70-100dB) | Absent | Present (70-100dB) | Absent | Present (70-100dB) | Absent | Present (70-100dB) | Absent | |||||
| Otoscopy | NAD* | - | 7 | - | - | - | - | 8 | - | - | - | - |
| Wax occlusion | - | 1 | - | - | - | - | 0 | - | - | - | - | |
| Tymps. | Type A | - | 8 | - | - | - | - | 8 | - | - | - | - |
| Acoustic reflexes | 500Hz | - | - | 7 | 1 | 5 | 3 | - | 8 | 0 | 7 | 1 |
| 1000Hz | - | - | 6 | 2 | 4 | 4 | - | 7 | 1 | 7 | 1 | |
| 2000Hz | - | - | 7 | 1 | 4 | 4 | - | 7 | 1 | 7 | 1 | |
| 4000Hz | - | - | 6 | 2 | 3 | 5 | - | 7 | 1 | 7 | 1 | |
| Pure-tone | WNL | - | 8 | - | - | - | - | 8 | - | - | - | - |
| Speech Audio | Speech Reception Threshold (SRT) | Good SRT:PTA < 5dB | 8 | - | - | - | - | 8 | - | - | - | - |
| Most Comfortable Level (MCL) | WNL (40 dB – 55dB above SRT) | 8 | - | - | - | - | 8 | - | - | - | - | |
| Threshold of Discomfort (TD) | WNL (90 dB – 110dB) | 3 | - | - | - | - | 4 | - | - | - | - | |
| < 90dB | 5 | - | - | - | - | 4 | - | - | - | - | ||
| Dynamic Range (DR) | < 60dB | 0 | - | - | - | - | 0 | - | - | - | - | |
| > 60dB | 8 | - | - | - | - | 8 | - | - | - | - | ||
| Speech Discrimination | Good discrimination (90% – 100%) | 8 | - | - | - | - | 8 | - | - | - | - | |
Hz, hertz; NAD, no abnormalities detected; Tymps, Tympanometry; PTA, Pure Tone Average; SRT, Speech Reception Threshold; WNL, Within Normal Limits.
FIGURE 3Configuration of participants’ audiograms.