Literature DB >> 32363765

Immediate vs conventional loading of Facility-Equator system in mandibular overdenture wearers: 1-year RCT with clinical, biological, and functional evaluation.

Alessandra J Schuster1, Raissa M Marcello-Machado2, Amália M Bielemann1, Anna Paula da Rosa Possebon1, Otacílio L Chagas Júnior3, Fernanda Faot4.   

Abstract

BACKGROUND: The use of immediate loading (IML) is still poorly explored in elderly patients and implant-retained mandibular overdenture (IMO) wearers. For this reason, more comparisons to conventional loading (CL) are required.
PURPOSE: To evaluate the clinical, biological, functional, and oral health-related quality of life (OHRQOL) influence of CL and IML loading on elders wearing IMO retained by the Facility-Equator system up to 1 year after implant installation.
MATERIAL AND METHODS: Twenty edentulous patients received two narrow diameter implants in the mandible; the loading type (CL or IML) was randomized. The clinical parameters were monitored along with prosthetic events, marginal bone loss (MBL) and bone level change (BLC), implant stability quotients (ISQ), masticatory performance outcomes, and Interleukin 1 beta (IL-1β) and tumor necrosis factor alpha (TNF-α) levels in the peri-implant crevicular fluid during the first year of loading. The OHRQoL was assessed via the Oral Health Impact Profile-EDENT questionnaire. Data were analyzed by the Mann-Whitney, χ2 , Wilcoxon paired, and McNemar tests.
RESULTS: After 1 year, MBL, BLC and ISQ were statistically identical (P > .05) in the CL and IML groups. The probing depth at 12 months in the CL group (2.19 mm) was higher than in the IML group (1.29 mm; P ≤ .0001). TNF-α was 33.6% higher in the CL group at 6 months (P = .043), while IL-1β was significantly higher in the IML group up to 6 months. The survival rate was 90% in the CL group and 85% in the IML group; 33 prosthetic events occurred in CL group and 23 in IML group.
CONCLUSIONS: After 12 months, both loading protocols are viable and result in similar clinical, biological, functional, and OHRQOL outcomes. However, IML generates better adaptation of the peri-implant tissues, faster improvement in OHRQoL and fewer prosthetic intercurrences than CL.
© 2020 Wiley Periodicals LLC.

Entities:  

Keywords:  conventional loading; immediate loading; implant-retained mandibular overdentures; narrow diameter implants

Year:  2020        PMID: 32363765     DOI: 10.1111/cid.12902

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  3 in total

1.  Circumferential bone level and bone remodeling in the posterior mandible of edentulous mandibular overdenture wearers: influence of mandibular bone atrophy in a 3-year cohort study.

Authors:  Alessandra Julie Schuster; Anna Paula da Rosa Possebon; André Ribeiro Schinestsck; Otacílio Luiz Chagas-Júnior; Fernanda Faot
Journal:  Clin Oral Investig       Date:  2021-12-02       Impact factor: 3.573

Review 2.  Unsplinted Attachments and Patient-Reported Outcome Measures (PROMs) in 2-Implant-Retained Mandibular Overdentures: A Systematic Review.

Authors:  Pravinkumar G Patil; Liang Lin Seow; Ting Jing Kweh; Smita Nimbalkar
Journal:  Int J Dent       Date:  2022-05-24

3.  Masticatory performances and maximum occlusal forces of immediate and conventional loaded two-implant supported overdentures retained by magnetic attachments: preliminary study of randomized controlled clinical trial.

Authors:  Awutsadaporn Katheng; Manabu Kanazawa; Yuriko Komagamine; Anna Miyayasu; Yoko Uehara; Daisuke Sato; Shunsuke Minakuchi
Journal:  Int J Implant Dent       Date:  2021-06-29
  3 in total