Literature DB >> 32361676

3D flow simulations and pressure measurements for the evaluation of cavitation dynamics and flow aggressiveness in ultrasonic erosion devices with varying gap widths.

Felix Schreiner1, Simon Paepenmöller2, Romuald Skoda3.   

Abstract

Cavitation induced wall loads at an ultrasonic horn facility are analyzed by 3D flow simulations and temporally high-resolved pressure measurements for varying gap widths between horn and stationary erosion specimen. Piezoelectric polyvinylidene fluoride (PVDF) probes are placed at different radial wall positions at the stationary specimen opposite of the oscillation horn and yield a declining flow aggressiveness with increasing radial position and gap width. The measurement results are reproduced by virtual probes in CFD simulations. Pressure measurement results yield a measure of flow aggressiveness in terms of wall load collectives that correlate well with incubation times obtained by erosion tests. A maximum aggressiveness at the specimen at 0.5mm gap width is obtained. Subharmonic frequencies associated with horn-attached void cavities increase with gap width which is well captured by the simulation. Due to the revealing of 3D flow patterns by the validated CFD results, detailed flow mechanisms associated with flow aggressiveness are discussed. The subharmonic frequency characteristics vs. gap width is associated with the shielding of the inner attached cavity region for small gaps and prevents the cavity from subharmonic collapse for several horn cycles. This shielding is less pronounced for larger gaps and leads to a shorter life time of the attached cavity and therefore to higher subharmonic frequencies.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Attached cavity; CFD; Cavitation erosion; PVDF sensor; Ultrasonic horn

Year:  2020        PMID: 32361676     DOI: 10.1016/j.ultsonch.2020.105091

Source DB:  PubMed          Journal:  Ultrason Sonochem        ISSN: 1350-4177            Impact factor:   7.491


  2 in total

1.  The Computational Fluid Dynamics (CFD) Analysis of the Pressure Sensor Used in Pulse-Operated Low-Pressure Gas-Phase Solenoid Valve Measurements.

Authors:  Dariusz Szpica; Grzegorz Mieczkowski; Andrzej Borawski; Vitalis Leisis; Saulius Diliunas; Tilmute Pilkaite
Journal:  Sensors (Basel)       Date:  2021-12-11       Impact factor: 3.576

2.  Challenges of numerical simulations of cavitation reactors for water treatment - An example of flow simulation inside a cavitating microchannel.

Authors:  Peter Pipp; Marko Hočevar; Matevž Dular
Journal:  Ultrason Sonochem       Date:  2021-07-08       Impact factor: 7.491

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.