A simple electrochemical approach to fabricate functionalized MWCNT-nanogold decorated PEDOT nanohybrid for simultaneous quantification of uric acid, xanthine and hypoxanthine.

Sarani Sen1, Priyabrata Sarkar2.   

Abstract

Medical diagnostics and detection of food spoilage require estimation of hypoxanthine (HX), xanthine (XN), and uric acid (UA). A selective sensing platform has been proposed for simultaneous detection of all these species. Functionalized multi-walled carbon nanotube (fMWCNT) stabilized nanogold decorated PEDOT:TOS polymeric nanocomposite (Au-PEDOT-fMWCNT) was synthesized through rapid one-step electropolymerization to enhance conductivity and active surface area by several folds. Electrochemical activities of the proposed sensing platform were analyzed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS). Analyses through SEM, FESEM and TEM were performed to explore the surface morphology and elemental analysis of the polymeric nanohybrid was investigated by XPS, Raman, FTIR, XRD spectroscopy. Electro-catalysis of UA, XN and HX occurred at low oxidation potentials i.e. 0.082, 0.463 and 0.808 V, respectively in the optimized conditions. The uniquely designed simple, interference free Au-PEDOT-fMWCNT/GCE sensor exhibited high selectivity, good reproducibility, reusability (∼180 times) and stability (∼3 month) with excellent sensitivity of 1.73, 14.31 and 3.82 μA μM-1 cm-2 for UA, XN and HX, respectively. The sensor exhibited linear ranges of detection as 0.1-800, 0.05-175 and 0.1-150 μM with detection limits of 199.3, 24.1 and 90.5 nM for quantification of UA, XN and HX respectively. The performance of the proposed sensor was validated by addition of UA, XN and HX in human serum, urine and fish samples by comparing to those using HPLC. The results indicated good applicability of the proposed sensor for simultaneous detection of UA, XN, HX in real biological fluids.
Copyright © 2020 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Au-PEDOT:TOS-fMWCNT; Differential pulse voltammetry; Electrochemical deposition; Nanocomposite; Poly-3,4-ethylenedioxythiophene; Real sample

Mesh:

Substances:

Year:  2020        PMID: 32359511     DOI: 10.1016/j.aca.2020.03.060

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  A photoelectrochemical sensor based on Z-Scheme TiO2@Au@CdS and molecularly imprinted polymer for uric acid detection.

Authors:  Junhong Zhao; Jing Cheng; Yudong Sun; Jiang Liu; Wen Chen; Yi Xu; Jiao Yang; Yingchun Li
Journal:  Mikrochim Acta       Date:  2021-05-15       Impact factor: 5.833

2.  A nonenzymatic reduced graphene oxide-based nanosensor for parathion.

Authors:  Sarani Sen; Anurag Roy; Ambarish Sanyal; Parukuttyamma Sujatha Devi
Journal:  Beilstein J Nanotechnol       Date:  2022-07-28       Impact factor: 3.272

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.