Literature DB >> 32357732

Input polarization-independent polarization-sensitive optical coherence tomography using a depolarizer.

Shivani Sharma1, Georg Hartl1, Sheeza K Naveed1, Katharina Blessing1, Gargi Sharma1, Kanwarpal Singh1.   

Abstract

Polarization-sensitive optical coherence tomography is gaining attention because of its ability to diagnose certain pathological conditions at an early stage. The majority of polarization-sensitive optical coherence tomography systems require a polarization controller and a polarizer to obtain the optimal polarization state of the light at the sample. Such systems are prone to misalignment since any movement of the optical fiber normally coupled to the light source will change the polarization state of the incident beam. We propose and demonstrate an input polarization-independent polarization-sensitive optical coherence tomography system using a depolarizer that works for any input polarization state of the light source. The change in the optical power at the sample for arbitrary input polarized light for the standard polarization-sensitive optical coherence tomography system was found to be approximately 84% compared to 9% for our proposed method. The developed system was used to measure the retardance and optical axis orientation of a quarter-wave plate and the obtained values matched closely to the expectation. To further demonstrate the capability of measuring the birefringent properties of biological samples, we also imaged the nail bed. We believe that the proposed system is a robust polarization-sensitive optical coherence tomography system and that it will improve the diagnostic capabilities in clinical settings.

Entities:  

Mesh:

Year:  2020        PMID: 32357732     DOI: 10.1063/5.0001871

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  2 in total

1.  Customized depolarization spatial patterns with dynamic retardance functions.

Authors:  David Marco; Guadalupe López-Morales; María Del Mar Sánchez-López; Ángel Lizana; Ignacio Moreno; Juan Campos
Journal:  Sci Rep       Date:  2021-05-03       Impact factor: 4.379

Review 2.  Advances in Optical Coherence Tomography Imaging Technology and Techniques for Choroidal and Retinal Disorders.

Authors:  Joshua Ong; Arman Zarnegar; Giulia Corradetti; Sumit Randhir Singh; Jay Chhablani
Journal:  J Clin Med       Date:  2022-08-31       Impact factor: 4.964

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.